Englisch, Revision 14, Date: 07.02.2017
34
5.2.2.3
(S)erial Output
Alterations within this menu need to be made effective by resetting the system (turn
the antenna off and then on). Dependent upon the alterations made, it may be neces-
sary to use a different baud rate / text document to call up the monitor (section 5.2.1
Figure 15
Menu: (S)erial Output
Input of
enables switching between 9600 and 19200 baud.
Select the desired procedure — 3964R or transparent — by pressing
. For procedure
3964R, in addition, the acknowledgement delay time (
) is adjustable. If procedure
’Monitor only’ is active, only baud rate and procedure can be selected. This is useful
whenever the serial output is solely required for parameter setting and the data output
is done via CAN or Profibus.
Via
it is possible to select whether the highest byte is to be output first or last. When
connecting this equipment with a Siemens PLC, this parameter has to be
0
(
High
Byte first
).
influences the composition of the output telegram.
Based on the values given in Table 8 „Data words in a telegram of 15 (14) byte length“
on page 20, you can define the desired elements of your telegram
by hexadecimal
addition. The sequence of the parameters cannot be influenced. It will always conform
to the sequence in the table!
Example
You only want to display the code and the status.
Add up the values 0x02 for the 32 code bits, 0x01 for STX as well
as the value 0x80 for status. Enter
0B
with
.
S:0843 X:+0748 Code: 12345678 Read: 65535
U[/mV]:20200 I[/mA]: 200 T[Grd.C]:+28 E: 0600 N: 2
Ftx[/Hz]:105960 Prog_Code: 00000000
(B)audrate: 9600
(P)rocedure 3964R
(O)rder of Data Transfer (0= HiByte first): 0
(T)elegram Content Mask [0..FF]: ff
(D)isplay Telegram Content
(C)har-Delaytime [1..220ms]: 220
(A)ck-Delaytime (3964R) [1.1680ms]: 1680
Co(n)tinous Telegrams 0
(S)erial Data Period [1..1000ms]: 8
(Q)uit Menue