Installation / Commissioning
Englisch, Revision 14, Date: 07.02.2017
12
3
Installation / Commissioning
NOTE!
Check the operating voltage before connecting! The cable
should not lie directly beside power supply cables.
Connect all necessary cables. For the next commissioning steps, connect a laptop
with the serial interface of the antenna. Antenna variants with RS422 interface
(HG 98780ZA/XA) require an appropriate interface converter. This interface converter
is not included in the scope of supply of this system. For further information, please
refer to the introduction in chapter 5 on page 28. Then start the monitor program as
described in section 5.2 on page 29.
Default values
In default the system uses the values of the file 1
(
Mon3964r.txt
; as listed in part 5.2.1 on page 29) with 9,600
Baud. Please keep in mind that another user could have
changed these values.
1.
Move a transponder into reception range.
The voltage
S
should increase significantly. The code should be detected imme-
diately and the number of readings has to be continuously counted up to 65535.
When moving the transponder in driving direction over the center axis of the
antenna, a positioning pulse should be generated.
2.
For setting the decoding thresholds (refer to section 5.2.2.2 „(T)ime & Code“ on
page 33) it is useful, to record a complete test run along the transponder track.
Antennas
HG 98780ZA
and
HG 98780WA
offer for this function the use of the
serial interface (section 5.2.2.6 „CS(V)“ on page 38) or the CAN Bus Message
Object 3 (section 4.2.6.4.4 on page 24 or 5.2.2.4 „C(A)N Parameters“ on page
36).
Antennas
HG 98780YA
and
HG 98780XA
offer for the same function the serial
interface (refer to section 5.2.2.6 on page 38) or the Profibus interface (refer to
section 5.2.2.5 on page 37). When using the Profibus interface, the necessary
parameters from the 16 byte data block are
System Status
,
Code
and
U-
Summe
.
Provided that the test run did not reveal any problems, changed parameters may be
saved and the monitor program may be terminated. Changing certain parameters re-
quires a complete system reset (switching the antenna off and on again), as described
in the corresponding section for the monitor program (section 5.2). This procedure en-
sures that the system is commissioned correctly.