Components and Operation
Englisch, Revision 14, Date: 07.02.2017
27
4.3
Accessories (optional)
4.3.1
Serial/parallel Converter HG 06150ZA/XA
Figure 12
Converter HG 06150XA for mounting bar installation
The serial/parallel converter has a casing which is suitable for mounting bar installa-
tion. To output the serial data via the RS 422 interface (ZA) or via RS232 (XA) the serial
output of the antenna has to be set to transparent protocol with the data contents
CODE
and system status as follows: Enter the value
83
within the corresponding submenu
for
Telegram Content Mask
(refer to section 5.2.2.3 on page 34). The Baud rate
must be set to 19200 Baud.
Out of this data stream the
code
is converted into a 16 Bit parallel output. The code
then contacts the outlets until the next code is received. In addition, 10 ms after the
code bits are applied a data ready pulse of 100 ms is generated as the antenna pass-
es over a transponder, i. e. the same transponder generates a new data ready pulse
as it enters the field again (e. g. when switching tracks).
The validity of the voltage, i. e. if a transponder is actually within reception range, is
displayed by the signal
Data_Valid
. If there is no transponder within the range, 0 V
is output. The parallel outputs,
Data_Ready
and
Data_Valid
are switched contra
+Usps (24V)
and are not current limited. In addition they are not potentially separat-
ed.
Byte #
Length
Significance
Type
Description
1
1 Byte
0x01
ASCII-061 : „=“
Start pulse
2,3,4,5
4 Byte
0x02
Unsigned long
Transponder code
6,7
2 Byte
0x80
Unsigned int
System status
8
1 Byte
Unsigned char
Check character
Table 18
Output format when using the serial/parallel interface