Software
Englisch, Revision 14, Date: 07.02.2017
29
If you are using a different port than
COM1
with HyperTerminal, then alter the port set-
ting as follows:
1.
Select
Properties
from the
File
menu (or click the Icon
). The following
window shows up (partly German version):
2.
Choose the respective port via the
Direct to
connection in the submenu.
Confirm with
. Save the altered values if you are asked for it when closing
HyperTerminal.
5.2
System monitor
In
monitor mode
it is possible to configure the system via a menu. To use the monitor
mode you need to know which protocol is preset in your antenna.
5.2.1
How to start the monitor program
Depending on the currently active procedure, the monitor program is started different-
ly (refer to section 5.2.2.3 on page 34).
5.2.1.1
Procedure Monitor only
If the antenna is set to the procedure „Monitor only“, the monitor mode is started 10 s
after switch on. In this case not files have to be transmitted and section 5.2.1.2 may be
ignored.
5.2.1.2
Procedures 3964R/transparent
The command to switch to monitor mode should be entered directly via a PC. To do
so, start your terminal program. For the startup, a set of configuration files is necessary
(small text files and HyperTerminal configuration files). These files are accessible for
download in the latest version from our internet server at
.
If HyperTerminal has been correctly installed, the terminal program can now be started
directly by double clicking the respective *.ht file (
Monitor9600.ht
for 9600 Baud
and
Monitor19200.ht
for 19200 Baud). If necessary, adapt the COM-port (refer to
section 5.1.1).