CAN Interface
English, Revision 01, Date: 14.04.2009
32
7.4.4.18 Manufacture parameter - calibration of the antenna
During the calibration the corresponding bit is set in the system status (TxPDO 1). For
the voltages Us1, Ud1 respectively Us2, Ud2 in TxPDO 2 the maxima of the calibration
are set, like they are put out in the calibration menu (see abouve). The average from
Udl and Udr is calculated.
The calibration should be proceeded at 10 kHz wire frequency as the frequency com-
pensation is also referred to this frequency.
Index
Sub Index
Name
Typ
Attr.
Map
Default
Meaning
0x2001
00
number of
parameter
Unsigned 8
RO
No
0x02
number of sub
indexes
01
Start Ant-1
calbration
Unsigned 32
W
No
./.
*)
Stop Ant-1
calbration
Unsigned 32
R
No
0x00000001
*)
02
Start Ant-2
calbration
Unsigned 32
W
No
./.
*)
Stop Ant-2
calbration
Unsigned 32
R
No
0x00000001
*)
*) By writing the signature “cali“ in ASCII code (hex-Code: 0x696C6163) or “ilac“ (hex-Code:
0x63616C69) on sub index 1 respectively 2 the corresponding calibrations are started und stopped by
reading sub index 1 respectively 2. After that the parameters should be saved. Furthermore a reset is
recommended.
Table 31
CAN: Manufacture Parameter - calibration of the antenna