Seal type/
Parameter
Standard seal,
BUNA/Carbon/
Ceramic
Optional seal,
EPR/Carbon /
Tungsten
Carbide
Optional seal,
FKM/Carbon /
Ceramic
Optional seal,
EPR/Silicon
Carbide/Silicon
Carbide
Optional seal,
EPR/Carbon /
Tungsten
Carbide with
external
flush
1,3,4
Packing
2
Maximum
glycol/water
concentration
50/50%
50/50%
50/50%
60/40%
50/50%
Not
recommended
Table notes
1. An external flush is required on low pressure systems that contain a high concentration
of abrasives.
2. Use packing on open or closed systems which require a large amount of makeup
water, as well as systems that are subjected to a wide variety of chemical conditions
and solids buildup.
3. For operating temperatures above 250°F, a cooled flush is required and is
recommended for temperatures above 225°F for optimum seal life. On closed
systems, cooling is accomplished by inserting a small heat exchanger in the flush line
to cool the seal flushing fluid.
4. Flush-line filters and sediment separators are available on request.
3 Product Description