LIMITED CONSUMER WARRANTY

For goods sold for personal, family or household purposes, Seller warrants the goods purchased hereunder (with the exception of 
membranes, seals, gaskets, elastomer materials, coatings and other “wear parts” or consumables all of which are not warranted except as 
otherwise provided in the quotation or sales form) will be free from defects in material and workmanship for a period of one (1) year from the 
date of installation or eighteen (18) months from the product date code, whichever shall occur first, unless a longer period is provided by law 
or is specified in the product documentation (the “Warranty”).

Except as otherwise required by law, Seller shall, at its option and at no cost to Buyer, either repair or replace any product which fails to 
conform with the Warranty provided Buyer gives written notice to Seller of any defects in material or workmanship within ten (10) days of 
the date when any defects or non-conformance are first manifest. Under either repair or replacement option, Seller shall not be obligated 
to remove or pay for the removal of the defective product or install or pay for the installation of the replaced or repaired product and Buyer 
shall be responsible for all other costs, including, but not limited to, service costs, shipping fees and expenses. Seller shall have sole discretion 
as to the method or means of repair or replacement. Buyer’s failure to comply with Seller’s repair or replacement directions shall terminate 
Seller’s obligations under this Warranty and render this Warranty void. Any parts repaired or replaced under the Warranty are warranted only 
for the balance of the warranty period on the parts that were repaired or replaced. The Warranty is conditioned on Buyer giving written notice 
to Seller of any defects in material or workmanship of warranted goods within ten (10) days of the date when any defects are first manifest.

Seller shall have no warranty obligations to Buyer with respect to any product or parts of a product that have been: (a) repaired by third 
parties other than Seller or without Seller’s written approval; (b) subject to misuse, misapplication, neglect, alteration, accident, or physical 
damage; (c) used in a manner contrary to Seller’s instructions for installation, operation and maintenance; (d) damaged from ordinary wear 
and tear, corrosion, or chemical attack; (e) damaged due to abnormal conditions, vibration, failure to properly prime, or operation without 
flow; (f) damaged due to a defective power supply or improper electrical protection; or (g) damaged resulting from the use of accessory 
equipment not sold or approved by Seller. In any case of products not manufactured by Seller, there is no warranty from Seller; however, 
Seller will extend to Buyer any warranty received from Seller’s supplier of such products.

Goulds Water Technology Policy Concerning Online Sales to Consumers. Homeowners using the Internet to locate information regarding 
residential water systems, residential wastewater systems, controls and tanks may discover several sites offering a direct-to-consumer 
purchasing opportunity.  Residential water and wastewater systems are mission critical applications and are designed to be installed by 
qualified professionals.  Goulds Water Technology has an extensive nationwide network of distributors and dealers, including authorized 
resellers.  For a complete view of Goulds Water Technology recognized distributors, dealers and authorized resellers, please refer to our 
locator at: http://goulds.com/sales-service/

No warranty is offered on Goulds Water Technology equipment purchased over the Internet, including web-based options from unauthorized 
retailers. This policy is necessary to ensure that Goulds Water Technology equipment is installed properly, in compliance with applicable laws, 
rules and codes, in a manner that addresses safety concerns and the proper performance of Goulds Water Technology equipment. 

THE FOREGOING WARRANTY IS PROVIDED IN PLACE OF ALL OTHER EXPRESS WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING BUT 
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE 
(1) YEAR FROM THE DATE OF INSTALLATION OR EIGHTEEN (18) MONTHS FROM THE PRODUCT DATE CODE , WHICHEVER SHALL OCCUR 
FIRST. EXCEPT AS OTHERWISE REQUIRED BY LAW, BUYER’S EXCLUSIVE REMEDY AND SELLER’S AGGREGATE LIABILITY FOR BREACH OF 
ANY OF THE FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMITED 
TO THE AMOUNT PAID BY THE BUYER FOR THE DEFECTIVE PRODUCT. IN NO EVENT SHALL SELLER BE LIABLE FOR ANY OTHER FORM OF 
DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL, CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, 
INCLUDING BUT NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE, LOSS OF INCOME, LOSS OF BUSINESS, 
LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not 
allow the exclusion or limitation of incidental or consequential damages, so the above exclusions may not apply to you. This warranty gives 
you specific legal rights, and you may also have other rights which may vary from state to state. 

To make a warranty claim, check first with the dealer from whom you purchased the product or visit www.xyleminc.com for the name and 

location of the nearest dealer providing warranty service.

Summary of Contents for IM105R06

Page 1: ...Sump Pumps INSTALLATION OPERATION AND MAINTENANCE MANUAL INSTRUCTION MANUAL IM105R06 ...

Page 2: ...ll as all local state and provincial codes The pump must be connected to a dedicat ed electrical circuit protected by a prop erly sized circuit breaker or fuses Install a disconnect where required by code Code questions should be directed to your electrical inspector See Chart 1 for specific information Disconnect electrical power before install ing or servicing the pump The motor s automatic ther...

Page 3: ... never by the power cord Place the pump against the basin wall so the switch is to the center See Installation Data 3 PIPING 4 INSTALLATION IN SUMP 1 GENERAL INFORMATION 1 1 Sump pumps are designed to operate inter mittently and usually seasonally It is recom mended that you test the pump before your rainy season begins to insure that the pump and switch are operating properly 1 2 We suggest insta...

Page 4: ... debris children or pets falling into the basin See Basin Style in Section 2 3 6 SEASONAL SERVICE MAINTENANCE 6 1 If your sump pump only operates seasonally and then sits idle for months it is recom 5 OPERATION 6 SEASONAL SERVICE MAINTENANCE mended that you test the pump before your rainy season begins Fill the sump with water and check for debris and proper switch operation Remove any debris whic...

Page 5: ...al 9 115 7 1 LSP07 10 1 20 1 WideAngleSwitch 12 5 6 5 12 3 8 15 6 8 230 3 5 SP024 2 4 1 SP025 10 1 VerticalSwitch 10 6 3 9 3 8 SP035 1 3 115 3 0 1 8 3 6 NoSwitch Manual Manual STS21 115 2 5 10 1 VerticalSwitch 20 1 Adjustable 11 3 16 10 4 5 NoSwitch 9 STS31 1 3 115 4 5 10 1 VerticalSwitch 20 1 Adjustable 11 3 16 10 4 5 NoSwitch 9 This is a D C motor It starts every 1 minute looking for a load If t...

Page 6: ... Angle Float Mounting Strap Figure 5 Tether length INSTALLATION DATA INSTALLATION DATA Typical Pump Installation in Sump Figure 3 PUMP ELECTRICAL PLUG CHECK VALVE PIGGYBACK SWITCH PLUG GROUNDED WALL OUTLET FLOAT SWITCH UNION 1 8 RELIEF HOLE PUMPING RANGE ...

Page 7: ...fective power supply or improper electrical protection or g damaged resulting from the use of accessory equipment not sold or approved by Seller In any case of products not manufactured by Seller there is no warranty from Seller however Seller will extend to Buyer any warranty received from Seller s supplier of such products Goulds Water Technology Policy Concerning Online Sales to Consumers Homeo...

Page 8: ...8 Bombas para sumideros MANUAL DE INSTALACIÓN Y OPERACIÓN MANUAL DE INSTRUCCIÓN IM105R06 ...

Page 9: ... a un circuito eléctrico dedicado protegido con un cort acircuitos o fusible del tamaño apropiado Instale un desconectador cuando el código así lo requiera Las preguntas acerca del código deben ser dirigidas al inspector eléctrico Ver la Tabla 1 para obtener infor mación específica Desconecte la corriente eléctrica antes de instalar o dar servicio a la bomba La protección automática contra la sobr...

Page 10: ...pide que la bomba se bloquee con aire La no perforación de este orificio es una de las 3 TUBERÍAS 1 INFORMACIÓN GENERAL 1 1 Las bombas para sumidero están diseñadas para funcionar intermitentemente y habitu almente por temporadas Se recomienda que pruebe la bomba antes del comienzo de la estación lluviosa para asegurar que la bomba y el interruptor estén funcionando correcta mente 1 2 Sugerimos in...

Page 11: ... una salida de corriente dedicada Luego conecte el enchufe macho estándar de la bomba a la parte trasera lado hembra del enchufe de los interruptores en tándem 4 6 Afiance los cables de alimentación a las tuberías de descarga con amarras o cinta aislante Enrolle y guarde el exceso de cable de alimentación fuera del sumidero 5 OPERACIÓN 5 1 Encienda la corriente en el panel de cort acircuitos y o i...

Page 12: ...orias 4 Motor defectuoso 5 Bloqueo con aire 6 Baja tensión 7 Carga del sistema demasiado alta 8 Bomba obstruida 9 Control de nivel defectuoso o interruptor situado incorrectamente 10 Dirección incorrecta de la válvula de retención 11 Fuga de la válvula de retención 12 Tamaño incorrecto del estanque o del pozo del sumidero 13 Flujo de entrada excesivo para el tamaño de la bomba 7 OPCIONES 7 1 El pr...

Page 13: ...9 115 7 1 LSP07 10 1 20 1 Interr de 12 5 6 5 12 3 8 15 6 8 230 3 5 ángulo ancho SP024 2 4 1 SP025 10 1 Interr vertical 10 6 3 9 3 8 SP035 1 3 115 3 0 1 8 3 6 Sin interr Manual Manual STS21 115 2 5 10 1 Interr vertical 20 1 Ajustable 11 3 16 10 4 5 Sin interr 9 STS31 1 3 115 4 5 10 1 Interr vertical 20 1 Ajustable 11 3 16 10 4 5 Sin interr 9 Éste es un motor de CC Arranca cada minuto buscando una c...

Page 14: ...pica de la bomba en el sumidero Figura 3 ENCHUFE ELÉCTRICO DE LA BOMBA VÁLVULA DE RETENCIÓN ENCHUFE DE INTERR EN TÁNDEM RECEPTÁCULO DE PARED CONECTADO A TIERRA INTERRUPTOR DE FLOTADOR UNIÓN ORIFICIO DE ALIVIO DE 1 8 PULG RANGO DE BOMBEO Curva del largo de la traba vs rango de bombeo Figura 4 Largo de la traba pulgadas Rango de bombeo ...

Page 15: ... uso de equipos accesorios no vendidos ni aprobados por el Vendedor En el caso de productos no fabricados por el Vendedor no habrá Garantía del Vendedor sin embargo el Vendedor transferirá al Comprador toda Garantía recibida del proveedor del Vendedor para dichos productos Política de Goulds Water Technology sobre ventas en línea a clientes Los propietarios que utilizan Internet para encontrar inf...

Page 16: ...16 Pompes de puisard MANUEL D INSTALLATION ET D UTILISATION MANUEL D UTILISATION IM105R06 ...

Page 17: ...cité On doit brancher la pompe à un circuit électrique indépendant protégé par un disjoncteur ou des fusibles de calibre ap proprié Poser un sectionneur si le code de l électricité l exige Adresser toute question relative au code à un inspecteur en électri cité Voir les informations sur les modèles dans la table 1 Couper l alimentation électrique de la pompe avant de procéder à l installation ou à...

Page 18: ...ngues périodes d arrêt saisonnières Modèle ST est art de l auto portrait venting aucun trou n est exigé 3 TUYAUTERIE 1 INFORMATIONS GÉNÉRALES 1 1 Les pompes de puisard sont conçues pour un usage intermittent généralement saisonnier Il est recommandé d essayer la pompe avant la fonte des neiges et le début des pluies printanières pour s assurer de son bon fonc tionnement et de celui du contacteur 1...

Page 19: ...tablir le courant au panneau de disjonc teurs ou au sectionneur ou aux deux si c est le cas 5 2 Remplir le puisard ou la cuve d eau et noter le niveau de l eau quand la pompe démarrage et arrête La pompe devrait démarrer bien avant que le puisard déborde et s arrêter avant que le niveau de l eau atteigne l orifice d aspiration On peut régler les cycles de marche et d arrêt des pompes à contacteur ...

Page 20: ...S ARRÊT DE LA POMPE V causes probables 7 8 9 10 et 13 RÉPÉTITION SANS ARRÊT DU CYCLE DE FONCTIONNEMENT V causes probables 9 11 12 et 13 CAUSES PROBABLES 1 Protecteur thermique déclenché 2 Disjoncteur ouvert ou fusible sauté 3 Pièces mobiles grippées 4 Moteur défectueux 5 Poche d air dans la pompe 6 Basse tension électrique 7 Hauteur de charge trop élevée du système 8 Pompe obstruée 9 Régulateur de...

Page 21: ...5 12 3 8 15 6 8 230 3 5 SP024 2 4 1 SP025 10 1 Vertical 10 6 3 9 3 8 SP035 1 3 115 3 0 1 8 3 6 Aucun contacteur Manuel Manuel STS21 115 2 5 10 1 Vertical 20 1 Réglable 11 3 16 10 4 5 Aucun contacteur 9 STS31 1 3 115 4 5 10 1 Vertical 20 1 Réglable 11 3 16 10 4 5 Aucun contacteur 9 Cette pompe alimentée en courant continu démarre à toutes les minutes à la recherche d une charge S il y a de l eau da...

Page 22: ...LA POMPE CLAPET DE NON RETOUR FICHE PRISE DU CONTACTEUR PRISE MURALE MISE À LATERRE RACCORD UNION TROU PUR GEUR D AIR DE 1 8 po PLAGE DE POMPAGE DONNÉES SUR L INSTALLATION DONNÉES SUR L INSTALLATION Courbe plage de pompage longueur du câble Figure 4 5 5 Longueur du câble po Plage de pompage po 3 5 CONTACTEUR À FLOTTEUR ...

Page 23: ...eur il n y a aucune garantie de la part du Vendeur toutefois le Vendeur prolongera à l Acheteur toute garantie reçue du fournisseur du Vendeur de tels produits Politique de Goulds Water Technology concernant les ventes en ligne aux clients Les propriétaires de maison utilisant l Internet pour trouver des informations concernant les systèmes d eau résidentielle les systèmes d eaux usées résidentiel...

Page 24: ...utilisé sous le permis Téflon est une marque déposée de Dupont 2016 Xylem Inc IM105 Révision numéro 6 Janvier 2016 Xylem Inc 2881 East Bayard Street Ext Suite A Seneca Falls NY 13148 Téléphone 866 325 4210 Télécopie 888 322 5877 www gouldswatertechnology com ...

Reviews: