Safety and Hazard Precautions
WARNING!
Electrical hazard!
Any work on the trailer refrigeration unit is allowed with
unplugged main plug only.
Protect the trailer refrigeration unit against being started up while
working on it by following suitable measures.
Never attempt to plug in or unplug the trailer refrigeration unit from the
power supply when your hands are wet.
WARNING!
Electrical hazard!
The following safety rules must be strictly observed before working on
the trailer refrigeration unit:
• Switch off.
• Prevent it from being switched back on again accidentally.
• Check that lines and equipment are without power.
• Ground and short circuit phases.
• Cover, partition or screen of adjacent line sections.
The electrical connection to the trailer refrigeration unit must be made
by a licensed electrician.
WARNING!
Hazard from toxic gas!
This refrigeration unit contains a fluorocarbon refrigerant, which, in the
presence of an open flame or electrical short, produces toxic gases
that are severe respiratory irritants capable of causing death.
The refrigerant tends to displace air and can cause oxygen depletion,
which may result in death by suffocation.
Be careful when working on the trailer refrigeration unit,
especially in any enclosed or confined area with a limited air
supply!
WARNING!
Fire and explosion hazard from flammable operating materials!
Avoid open fire, electrical sparks and ignition sources.
Do not smoke!
Observe measures for fire and explosion protection.