Page 3231
Magnetic motor and balanced main and
driven gear
1. Maintenance instructions 7. Inspection of magneto stator and rotor
2. Removal of left crankcase cover 8. Inspection of balanced main and driven gears
3. Disassembly of magneto stator and rotor 9. Inspection of left body oil pump
4. Removal and inspection of balance main and driven gears 10. Installation of left
body oil pump
5. Removal of left oil pump 11. Installation of balanced main and driven gears
6. Inspection of left crankcase cover 12. Installation of magneto stator and rotor
13. Installation of left crankcase cover
Maintenance notice
The removal and installation of the magneto and the balance main and driven gears described
in this section can be completed only by removing the left crankcase cover
without removing the
engine
.
Removal of left crankcase cover
Remove the fastening bolts of the left front
cover and take off the left crankcase cover;
Disassembly of the magneto
stator
1. Remove the 2 bolts M5
×
10 fastening
screws of the sensor;
2. Remove the 2 screws M5
×
40 fastening
screws of the stator coil, and then remove the
magneto stator assembly from the left crankcase
cover.
Disassembly of the magneto rotor
Remove the magneto rotor lock nut, and
use a
special tool to remove the magneto rotor
.
M5×40
M5
×
10
Magneto stator combination