Outlet Valve Fitting Repair
3A2853C
23
Outlet Valve Fitting Repair
NOTE:
Before doing any repair to pump, perform
Flushing Sprayer
procedure, page 15.
Removal
1.
Engage trigger lock and pull prime/spray valve UP
to release pressure.
2.
Remove battery.
3.
Remove outlet valve fitting access plug.
4.
Use tool (supplied) to loosen and remove outlet
valve fitting. Make sure old o-ring, seat, outlet valve
fitting, and spring are out of pump outlet cavity.
Installation
1.
Screw outlet valve fitting into threads. Use tool
(supplied) and tighten to 8 ft-lb (11 N•m).
2.
Press outlet valve fitting access plug into place.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing fluid
and moving parts, remove battery and follow the
Pressure Relief Procedure
when you stop spraying
and before cleaning, checking, or servicing the
equipment.
Move sprayer to a non-hazardous area before servicing.