Pressure Relief Procedure
2
332561D
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1.
Perform
Grounding Procedure
if using flammable
materials.
2.
Set pump valve
OFF
. Turn engine
OFF
.
3.
Turn pressure control to lowest setting.
4.
Trigger gun to relieve pressure.
5.
Engage gun trigger safety.
6.
Turn prime valve down.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
ti6740a
ti3441a
ti3305a
ti3324a
ti6473a