Troubleshooting
Error
Code
Error
Location
Type
Name
Cause
Solution
L1AX
Low Chemical
Level A
L1BX
ADM
ALARM
Low Chemical
Level B
Tanks low on material.
Fill tanks with material.
MBN0 MCM
ADVI-
SORY
Motor Brush
Wear
Brushes have worn
down and need
replacing.
Replace Brushes. See
System Repair manual.
MMU-
X
USB
ADVI-
SORY
USB Log Full
USB logs have reached
a level were data loss
will occur if logs are not
downloaded.
Use a USB drive and
download all logs.
P4AX
Over Pressure A System pressurized
before allowing heat to
reach setpoint.
Turn on the heat and allow
the hose to reach the
setpoint before turning on
the pumps.
Bad pressure
transducer.
Verify the ADM pressure
reading the analog gauges
at the manifold. Replace
transducers if they do not
match.
P4BX
MCM
ALARM
Over Pressure B
E-XP2i system
configured as E-30i.
Ensure rotary switch on
MCM is set to position 0 for
E-30i.
P6AX
Pressure
Transducer Fault
A
Loose/bad connection.
Check to ensure the
pressure transducer is
properly installed and
all wires are properly
connected.
P6BX
MCM
ALARM
Pressure
Transducer Fault
B
Bad sensor.
See if the error follows the
transducer. Disconnect
transducer cable from
#8 and #9 connectors
on MCM. Reverse A
and B connections and
check if the error follows.
If the error follows the
transducer, replace the
pressure transducer. See
system repair manual. If
the error does not follow,
replace MCM. See system
repair manual.
78
3A1705E
Summary of Contents for 259079
Page 34: ...Setup A5 A1 A2 AS AN A3 AT A3 A4 A2 A6 A4 34 3A1705E...
Page 45: ...Advanced Display Module ADM Operation Setup Screens Navigation Diagram Figure 35 3A1705E 45...
Page 49: ...Advanced Display Module ADM Operation Run Screens Navigation Diagram Figure 36 3A1705E 49...
Page 93: ...Dimensions Dimensions Top View Figure 43 Side View Figure 44 3A1705E 93...
Page 95: ...Dimensions Pallet Mounting Dimensions Figure 48 3A1705E 95...
Page 97: ...Notes Notes 3A1705E 97...