Installation
3A5354B
11
Connect Electrical Cord
NOTE:
The installed strain relief bushing (SR) fits a
0.71-0.98 in. (18-25 mm) OD electrical cord.
1. Turn the main power switch (MP) OFF.
2. Open the electrical enclosure door (ED).
3. Insert the electrical cord through the electrical
enclosure strain relief bushing (SR).
4. Attach insulated ferrules to the end of each wire.
5. Connect the ground wire (DA) to the chassis ground
(DB).
6. Connect power wires to the main power switch (MP)
as shown below.
NOTE:
Use a flat-head or Pozidriv screwdriver to tighten
the terminals to 7-10 in-lb (0.8-1.1 N•m).
7. Tighten the strain relief bushing (SR) around the
electrical cord.
8. Close the electrical enclosure door (ED).
F
IG
. 8
SR
ED
I ON
O OFF
MP
DB
DA
ti31214a