Repair
34
3A5354B
Replace Pump Heaters and
Sensor O/T Device
1. Turn the main power switch (MP) OFF.
2. Disconnect the cable connector (UB) from the pump
receptacle (UA) on the pump shroud (UC).
3. Remove the four screws from the back pump
shroud.
F
IG
. 38
UB
UC
UA
F
IG
. 39
Screws