background image

Pressure Relief Procedure

Pressure

Pressure

Pressure Relief

Relief

Relief Procedure

Procedure

Procedure

Follow the Pressure Relief Procedure
whenever you see this symbol.

This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as splashing
fluid, follow the Pressure Relief Procedure when
instructed.

1.

Close the abrasive ball valve (M).

2.

Close the compressor supply air valve, then turn
the compressor off.

3.

Engage the blast control switch (B) to relieve
pressure in the system.

4.

Verify that the supply pressure gauge (ZC) reads
0 psi. Then disconnect the air inlet hose from the
system.

5.

Turn the selector valve (W) to OFF.

6.

Open the pot dump valve (J) until the pot
pressure gauge (L) reads 0 psi.

Grounding

Grounding

Grounding

(ATEX

(ATEX

(ATEX systems

systems

systems only)

only)

only)

The equipment must be grounded to reduce the
risk of static sparking. Static sparking can cause
fumes to ignite or explode. Grounding provides an
escape wire for the electric current.

Systems:

Systems:

Systems: Use supplied ground wire and clamp
(237686).

Air

Air

Air and

and

and fluid

fluid

fluid hoses:

hoses:

hoses: Use only genuine Graco ATEX

rated, conductive blast hoses with a maximum of
150 ft (45 m) combined blast hose length to ensure
grounding continuity. Check the electrical resistance
of the blast hoses. If the total resistance to ground
exceeds 29 megaohms, replace the blast hose
immediately.

Air

Air

Air compressor:

compressor:

compressor: follow manufacturer’s

recommendations.

10

3A3489A

Summary of Contents for 262950

Page 1: ...g removal removal removal and and and surface surface surface preparation preparation preparation For For For professional professional professional use use use only only only Important Important Important Safety Safety Safety Instructions Instructions Instructions Read all warnings and instructions in this manual Save these instructions 175 psi 12 06 bar 1 2 MPa Maximum Working Pressure See page ...

Page 2: ...sh Feature 19 Refilling the Pot with Abrasive 20 Shutting Down 20 Draining the Pot 21 Winterizing the Equipment 22 Cleaning the Water Tank 23 Using the Water Dose Meter 23 Troubleshooting 24 Repair 30 Replacing the DataTrak Battery 30 Replacing the DataTrak Fuse 31 Replacing the Pinch Hose 32 Parts 33 EQm Parts 33 EQs Parts 35 EQs2 Parts 39 EQC Parts 43 EQ200T Parts 45 EQ400T3 Parts 47 EQ400T4i Pa...

Page 3: ...X 262970 Elite Skid 262974 EcoQuip2 EQs Elite Vapor Blast System II 2G c ia IIAT3 X 262980 Twinline 262984 EcoQuip2 EQs2 Elite Vapor Blast System II 2G c ia IIAT3 X 262990 EcoQuip2 EQ200T Elite Vapor Blast System T4i T4i T4i 262993 T3 T3 T3 Trailer 262996 EcoQuip2 EQ400T Elite Vapor Blast System T4i T4i T4i Related Related Related Manuals Manuals Manuals Manual Manual Manual Number Number Number P...

Page 4: ...ms systems systems only only only Ground all equipment in the work area See Grounding Grounding Grounding Instructions Instructions Instructions All label and marking material must be cleaned with a damp cloth or equivalent DUST DUST DUST AND AND AND DEBRIS DEBRIS DEBRIS HAZARD HAZARD HAZARD Use of this equipment can result in the release of potentially harmful dust or toxic substances from the ab...

Page 5: ...solvent manufacturer s warnings For complete information about your material request Safety Data Sheets SDSs from distributor or retailer Do not leave the work area while equipment is energized or under pressure Turn off all equipment and follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure when equipment is not in use Check equipment daily Repair or replace wor...

Page 6: ...nch cut or amputate fingers and other body parts Keep clear of moving parts Do not operate equipment with protective guards or covers removed Pressurized equipment can start without warning Before checking moving or servicing equipment follow the Pressure Pressure Pressure Relief Relief Relief Procedure Procedure Procedure and disconnect all power sources PERSONAL PERSONAL PERSONAL PROTECTIVE PROT...

Page 7: ...Notes Notes Notes Notes 3A3489A 7 ...

Page 8: ...System Component Identification System System System Component Component Component Identification Identification Identification 8 3A3489A ...

Page 9: ...ve U Water Pump Inlet Filter Key Key Key V Blast Air Pressure Gauge W Selector Valve X Rinse Ball Valve Y Air Supply Connection Z Blast Connection ZA Pneumatic Control Connection ZB Electric Control Connection non ATEX systems only ZC Supply Pressure Gauge ZD MediaTrak ZE Accessory Extension Hose ZF Abrasive Material ZG Pot Outlet Manifold ZH Ground Wire and Clamp ATEX systems only ZJ Step ZK Floa...

Page 10: ...elector valve W to OFF 6 Open the pot dump valve J until the pot pressure gauge L reads 0 psi Grounding Grounding Grounding ATEX ATEX ATEX systems systems systems only only only The equipment must be grounded to reduce the risk of static sparking Static sparking can cause fumes to ignite or explode Grounding provides an escape wire for the electric current Systems Systems Systems Use supplied grou...

Page 11: ...ctric or pneumatic blast control switch can be used with hose lengths less than 150 ft 45 m Blasting with 150 ft 45 m or more of blast hose requires the use of an electric blast control switch Blasting Blasting Blasting on on on Higher Higher Higher Surfaces Surfaces Surfaces NOTICE NOTICE NOTICE When blasting on a surface higher than the equipment make sure that there is a length of blast hose on...

Page 12: ...4 Open the compressor air supply valve 175 psi 12 06 Bar 1 2 MPa maximum compressor supply NOTE NOTE NOTE Make sure the air supply meets the appropriate air flow requirements see Technical Specifications page 66 5 Connect the blast hose hose restraints control hoses and coupler pins NOTICE NOTICE NOTICE Do not use a wrench when installing the nozzle Damage to the seal could occur To avoid seal dam...

Page 13: ... Close the water dose meter S if equipped 3 Turn the selector valve to OFF 4 Disengage the emergency stop Q 8 8 0 0 0 0 0 NOTE NOTE NOTE The water pump will not work unless the Emergency Stop is disengaged 5 Align the pop up handle with the pin slot and then firmly push and turn the handle 90 after the pin is below the bracket slot Proper engagement of the pin will hold the pop up down until it is...

Page 14: ...ear any abrasive from the pop up and gasket Make sure water is above the pop up seal and pop up seal is closed Failure to do so before pressurizing the pot can result in serious injury to the operator 10 When the water level is above the pop up gasket rotate the handle to release the pop up pin 11 Turn the selector valve to BLAST 12 Engage the blast control switch and set the blast air pressure to...

Page 15: ... the blast force as necessary to clean without doing any damage to the substrate EQs2 EQs2 EQs2 Elite Elite Elite Blast Blast Blast Pressure Pressure Pressure Setting Setting Setting 1 Turn both blast pressure regulators all the way in CW 2 Blast with nozzle one and nozzle two and record the blast pressure from the blast pressure gauge 3 Blast with nozzle one and set the blast pressure at or below...

Page 16: ...rasive Abrasive Metering Metering Metering Valve Valve Valve To optimize performance use the High Production or Media Efficient lines on the charts CPM set points near the High Production lines will yield the highest removal rates and the highest media consumption rates To maximize removal rate regardless of media consumption use the highest possible blast pressure and set the CPM to the highest a...

Page 17: ...Operation General General General Application Application Application Guides Guides Guides 3A3489A 17 ...

Page 18: ... 41 MPa 137 3 9 190 5 4 225 6 4 234 6 6 256 7 2 362 10 3 391 11 1 70 psi 4 8 bar 0 48 MPa 166 4 7 225 6 4 251 7 1 269 7 6 293 8 3 422 11 9 447 12 7 80 psi 5 5 bar 0 55 MPa 188 5 3 244 6 9 281 8 0 298 8 4 337 9 5 460 13 0 498 14 1 90 psi 6 2 bar 0 62 MPa 210 5 9 266 7 5 293 8 3 317 9 0 374 10 6 520 14 7 562 16 0 100 psi 6 9 bar 0 69 MPa 239 6 8 283 8 0 327 9 3 378 10 7 413 11 7 561 15 9 601 17 0 11...

Page 19: ...ash feature on any surface other than where you have blasted or intend to blast It will affect dull the surface NOTICE NOTICE NOTICE Do not use the wash feature on wood that has been blasted It could damage the wood and cause the grain to rise Wait for the wood to dry and then use a broom brush or vacuum to remove any residual abrasive 1 Close the abrasive ball valve M 2 Turn the selector valve to...

Page 20: ...ring and turning the handle 90 to hold the pop up in the open position 5 Add the abrasive see Technical Specifications page 66 for capacity information and continue to step 8 from Setting Up the Equipment page 13 Shutting Shutting Shutting Down Down Down 1 When you have finished blasting perform wash until all of the abrasive is flushed from the blast hose See Using the Wash Feature page 19 2 Turn...

Page 21: ...alve to BLAST This will pump the abrasive out through the abrasive hose 4 Place a bucket under the abrasive hose Slowly open and close the abrasive ball valve to flush abrasive material from the pot Repeat several times Once no abrasive material flows from the hose close the abrasive ball valve Turn the selector valve to OFF 5 Engage the pop up pin to hold the pop up open and allow air to enter 6 ...

Page 22: ...ly Disconnect the water inlet regulator from the pump and install the winterizing tube Insert the winterizing tube into a windshield washer fluid container Continue to step 5 5 Turn the selector valve to WASH and open the rinse ball valve While holding the rinse hose over the pot run the pump until windshield wash comes out of the rinse hose 6 Move the selector valve into the other two positions B...

Page 23: ...e the tank lid and clean out with pressure washer Using Using Using the the the Water Water Water Dose Dose Dose Meter Meter Meter The water dose meter is a feature used on EcoQuip2 Elite models only This feature allows the user to adjust how wet the blast will be during operation 1 Follow steps 1 11 on Setting Up the Equipment page 13 2 Adjust the water dose valve S to adjust how wet the blast wi...

Page 24: ...age 33 or EQs2 Parts page 39 Check the inlet water pressure regulator screen filter for debris clean if possible If no flow can pass through the regulator replace it The water pump air regulator is malfunctioning Disengage the blast control switch B Adjust the pump inlet air pressure regulator until the pump air pressure regulator gauge reads 100 psi 6 9 bar 0 69 MPa If you are unable to attain th...

Page 25: ...s engaged Large slugs of abrasive and water are ejected from nozzle The pinch hose is worn With the pot pressurized and the abrasive ball valve open check to make sure the pump is stalled If the pump rod is creeping replace the pinch hose See Replacing the Pinch Hose page 32 The water pressure regulator is malfunctioning Adjust the water pressure regulator to 185 psi 12 75 bar 1 275 MPa If this ad...

Page 26: ... air compressor for proper setup The electric blast control circuit is malfunctioning Make sure proper 12V supply is connected and at full charge Inspect the cable for damaged or shorted wiring Check the 3A fuse and replace if necessary Check for continuity through the connectors on the control box P and all external cables Check continuity through the electric blast control switch the switch is n...

Page 27: ...e 21 followed by the Pressure Relief Procedure page 10 With the abrasive hose disconnected inspect the interior of the pinch hose for obstructions or debris and replace if necessary see Replacing the Pinch Hose page 32 Remove the tri clamp from the bottom of the pot Inspect the bottom of the pot and the abrasive hose for obstructions or debris The pot pressure is too low With the blast control dis...

Page 28: ... is clean remove the exhaust mufflers from the 4 way and check for debris Clean the ports and replace the mufflers if necessary If all above items are functional replace the 4 way solenoid valve The supply air pressure is fluctuating Make sure the compressor meets minimum flow requirements and is operating properly See Technical Specifications page 66 for more information on flow requirements The ...

Page 29: ... an obstruction inside the pot or inside the abrasive hose between the pot and the enclosure Perform Draining the Pot page 21 followed by Pressure Relief Procedure page 10 With the abrasive hose disconnected inspect the interior of the pinch hose for obstructions or debris and replace if necessary see Replacing the Pinch Hose page 32 Remove the tri clamp from the bottom of pot Inspect the bottom o...

Page 30: ...s warranty Replace Replace Replace Battery Battery Battery 1 Unscrew cable from the back of the reed switch assembly 2 Remove the cable from the two cable clips 3 Remove the DataTrak module from the bracket Take the module and attached cable to a non hazardous location 4 Remove the two screws on the back of the module to access the battery 5 Disconnect the used battery and replace it with an appro...

Page 31: ...able Use of an unapproved fuse will void Graco s warranty Replace Replace Replace Fuse Fuse Fuse 1 Remove the screw metal strap and plastic holder 2 Pull the fuse away from the board 3 Replace with an approved fuse Approved Approved Approved Fuses Fuses Fuses DataTrak DataTrak DataTrak Part Part Part Number Number Number Series Series Series Letter Letter Letter Fuse Fuse Fuse Required Required Re...

Page 32: ...e pulling 7 Loosen the remaining hose clamp and remove the pinch hose from the circuit Installing Installing Installing the the the Pinch Pinch Pinch Hose Hose Hose 1 Place both hose clamps C1 C2 on the pinch hose PH Leave 1 4 in of hose exposed on the ends 2 Slide the pinch hose PH onto the barb at the blasting circuit BC 3 Reinstall the blasting circuit BC and pinch hose PH into the box through ...

Page 33: ...all non swivel pipe threads 2 Apply anti seize to threads 3 Torque to 60 5 ft lb 81 3 6 7 N m with pot pressurized 4 Torque to 15 2 ft lb 20 3 2 7 N m 5 Apply anti seize to enclosure mounting studs 6 Torque to 25 30 ft lb 34 40 6 N m 8 Apply anaerobic sealant to threads 3A3489A 33 ...

Page 34: ... MANIFOLD unequal tee 1 13 17L317 CLAMP tri clamp 1 5 hex wing nut 1 14 17L329 HOSE inlet media 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 15 17J332 VALVE ball 1 npt brass nickel 1 16 17J329 COUPLER cam lock sst 1 nptf 1 17 112306 PLUG pipe 3 8 npt sst 1 18 17J331 GASKET cam lock buna 1 0 2 19 502598 GASKET sanitary PTFE 2 20 17J289 LABEL instructions 1 21 EQ1051 ...

Page 35: ...Parts EQs EQs EQs Parts Parts Parts 1 Apply thread sealant to all non swivel pipe threads 2 Apply anti seize to threads 3 Torque to 60 5 ft lb 81 3 6 7 N m 4 Torque to 15 2 ft lb 20 3 2 7 N m 3A3489A 35 ...

Page 36: ...1 40 17J331 GASKET cam lock buna 1 0 2 41 128226 NUT flange 3 8 16 sst 4 128226 NUT flange 3 8 16 sst 16 42 26A014 CABLE deadman battery male 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 43 EQ1934 COUPLER sandblast 1 1 2 npt f 1 44 190774 BLANK label kit 1 46 502598 GASKET sanitary PTFE 2 47 EQ1051 GASKET blast nozzle 2 48 17J944 LABEL brand EcoQuip EQs 1 17J945 LAB...

Page 37: ...ontinued continued continued 1 Apply thread sealant to all non swivel pipe threads 2 Apply anti seize to threads 3 Torque to 60 5 ft lb 81 3 6 7 N m with the pot pressurized 4 Torque to 15 2 ft lb 20 3 2 7 N m 3A3489A 37 ...

Page 38: ...1v 17L635 BRACKET pop up ring 2 1x 128504 BOLT flange hd serrated 1 4 ss 4 1y 17L632 HANDLE T pop up weldment 1 1aa 17K045 SWIVEL union 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 1bb 17K045 FITTING elbow 3 4 npt sst 1 1cc 17J343 VALVE ball 3 4 npt brass nickel 2 1dd 190724 NIPPLE sst 1 1ee EQ7004 FITTING hose garden 3 4 in mpt 1 1ff 17K045 FITTING bushing 1 1gg 17...

Page 39: ...Parts EQs2 EQs2 EQs2 Parts Parts Parts 1 Apply thread sealant to all non swivel pipe threads 3A3489A 39 ...

Page 40: ...8 2 54 MANIFOLD air inlet dual frame EQ2 1 56 128818 BOLT button hd 3 8 16 x 2 75 10 59 128934 FITTING swivel elbow 1 1 2 npt cs 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 74 17L078 BRACKET manifold dual frame EQ2 1 75 17L119 KIT nozzle gasket 4 76 128483 GROMMET pump EQ2 1 82 17J958 TOOL pressure verification 1 83 17K875 HOSE air dual system short 1 84 17K876 HOS...

Page 41: ...Parts EQs2 EQs2 EQs2 continued continued continued 1 Apply thread sealant to all non swivel pipe threads 3A3489A 41 ...

Page 42: ... 128504 4 27 EQ1475 NUT lock nylon insert 1 2 sst 2 33 17L642 VALVE ball 3 8 npt sst 2 34 EQ1627 FITTING nipple barb hose 3 8 in 2 37 167702 NIPPLE pipe 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 38 128819 BOLT flange hd serrated 1 2 ss 8 39 128226 NUT flange 3 8 16 sst 33 41 128504 BOLT flange hd serrated 1 4 ss 8 45 EQ1934 COUPLER sandblast 1 1 2 npt f br 2 48 1...

Page 43: ...ealant to all non swivel pipe threads 2 Apply anti seize to threads 3 Torque to 60 5 ft lb 81 3 6 7 N m with pot pressurized 4 Torque to 15 2 ft lb 20 3 2 7 N m 5 Apply anti seize to enclosure mounting studs 6 Torque to 25 30 ft lb 34 40 6 N m 3A3489A 43 ...

Page 44: ...7J289 LABEL instructions 1 21 502598 GASKET sanitary PTFE 2 22 EQ1051 GASKET blast nozzle 2 24 17D787 PIN safety item hose hair c 2 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 25 206994 FLUID TSL 8 oz bottle 1 26 EQ1829 FITTING ground boss spud 1 1 2 in 1 28 EQ1002 VALVE ball 3 8 npt sst 1 29 EQ1627 FITTING nipple barb hose 3 8 in 1 32 17K344 FITTING elbow 3 4 npt ss...

Page 45: ...Parts EQ200T EQ200T EQ200T Parts Parts Parts 1 Apply thread sealant to all non swivel pipe threads 3A3489A 45 ...

Page 46: ... 1 19 128934 FITTING swivel elbow 1 1 2 npt cs 1 21 129011 FITTING elbow 90 fxf cs 1 22 129012 FITTING reducer mxf cs 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 23 129010 FITTING elbow 45 mxf cs 1 27 24Z156 KIT replacement tool box 1 28 24Z156 INSERT foam tool box EcoQuip 1 29 17K025 STRAINER pressure pot 2 30 EQ1844 FUSE blade 3A 2 31 17J331 GASKET cam lock buna ...

Page 47: ...Parts EQ400T3 EQ400T3 EQ400T3 Parts Parts Parts 1 Apply thread sealant to all non swivel pipe threads 3A3489A 47 ...

Page 48: ...7K878 HOSE air trailer system GL10 1 19 128934 FITTING swivel elbow 1 1 2 npt cs 1 21 129009 FITTING elbow 90 mxf cs 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 27 24Z156 KIT replacement tool box 1 28 24Z156 INSERT foam tool box EcoQuip 1 29 17K025 STRAINER pressure pot 2 30 EQ1844 FUSE blade atc 3A 2 31 17J331 GASKET cam lock buna 1 0 2 32 17L633 TOOL EQ wrench 2 ...

Page 49: ...Parts EQ400T4i EQ400T4i EQ400T4i Parts Parts Parts 1 Apply thread sealant to all non swivel pipe threads 3A3489A 49 ...

Page 50: ...railer system GL10 1 19 128934 FITTING swivel elbow 1 1 2 npt cs 1 20 17L644 VALVE ball 1 1 4 npt sst 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 21 129009 FITTING elbow 90 mxf cs 1 27 24Z156 KIT replacement tool box 1 28 24Z156 INSERT foam tool box EcoQuip 1 29 17K025 STRAINER pressure pot 2 30 EQ1844 FUSE blade atc 3A 2 31 17J331 GASKET cam lock buna 1 0 2 32 17L...

Page 51: ... Parts Parts Parts 1 Torque fitting with pump outlet fitting to 35 40 ft lb 47 4 54 2 N m 3 Apply thread sealant to needle valve knob screw when reassembling Align knob with D facing up when in closed position 4 Apply thread sealant to selector valve handle set screw when reassembling 3A3489A 51 ...

Page 52: ... 2 49 EQ1115 BULKHEAD connector union 3 8 in 2 52 112268 SWIVEL union 1 53 17L324 REGULATOR pressure water 185 psi 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 54 17K055 VALVE selector 3 way 3 8 npt br 1 55 118160 WASHER lock external 1 56 EQ1832 FITTING tee branch swivel male 2 57 EQ1122 FITTING elbow stem 3 8 in 5 68 127917 NUT flange serrated 1 4 20 ss 4 70 11179...

Page 53: ...Parts Enclosure Enclosure Enclosure Parts Parts Parts continued continued continued 2 Apply thread sealant to emergency stop valve stem when reassembling the red knob 3A3489A 53 ...

Page 54: ...3 8 1 51 17K053 VALVE solenoid elec pneu assy 1 51 17K054 VALVE pilot 4 way 1 51 17K053 KIT solenoid electric pneu 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 57 EQ1122 FITTING elbow stem 3 8 in 3 58 EQ5108 VALVE 3 way e stop 3 8 in fpt 3 1 59 EQ1438 VENT breather 3 8 npt 1 63 127908 NUT flange serrated 10 32 ss 2 68 127917 NUT flange serrated 1 4 20 ss 5 69 17C001...

Page 55: ...Parts Enclosure Enclosure Enclosure Parts Parts Parts All All All models models models except except except EQm EQm EQm 3A3489A 55 ...

Page 56: ...ry 1 5 inch 1 18 MANIFOLD blast circuit 1 5 bottom 1 19 680454 GASKET sanitary fitting 3 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 21 MANIFOLD slurry barb cam lock 1 33 128638 FITTING ptc straight 3 8 1 45 128637 FITTING ptc straight 1 4 1 60 17L317 CLAMP tri clamp 1 5 hex wing nut 3 61 17K051 HOSE pinch 1 62 128642 CLAMP hose t bolt 1 75 2 00 sst 2 73 128787 BOLT ...

Page 57: ...Parts Enclosure Enclosure Enclosure Parts Parts Parts EQm EQm EQm only only only 3A3489A 57 ...

Page 58: ...blast circuit 1 0 bottom 1 19 680454 GASKET sanitary fitting 3 21 MANIFOLD slurry barb cam lock 1 Ref Ref Ref Part Part Part Description Description Description Qty Qty Qty 33 128638 FITTING ptc straight 3 8 1 45 128637 FITTING ptc straight 1 4 1 60 17L317 CLAMP tri clamp 1 5 hex wing nut 3 61 17K051 HOSE pinch 1 62 128642 CLAMP hose t bolt 1 75 2 00 sst 2 73 128787 BOLT button hd 3 8 16 x 3 4 ss ...

Page 59: ... screws fh sst 8 pk 1 7 17H240 KIT cable ties 6 pk 1 8 17C124 GASKET brass blast coupler 1 9 17D786 KIT replacement whipcheck 1 10 17D787 KIT replacement hairpin hose 1 11 17L327 CONNECTOR twist lock m 1 12 17L328 CONNECTOR twist lock f 1 13 EQ1336 1 4 QD f 1 8 npt f 1 14 EQ1421 1 4 QD m 1 4 npt f 1 15 EQ1813 1 4 QD f 1 4 npt m 1 26A024 26A024 26A024 1 25 1 25 1 25 in in in 26A074 26A074 26A074 1 ...

Page 60: ...rt ID ID ID Blast Blast Blast Control Control Control Coupler Coupler Coupler 1 1 1 Coupler Coupler Coupler 2 2 2 Length Length Length ATEX ATEX ATEX Approved Approved Approved 17L474 1 0 in Nozzle holder brass 17L475 1 0 in 2 Prong coupler brass 17L472 1 25 in Nozzle holder brass 17L473 1 25 in None 2 Prong coupler brass 2 Prong coupler brass 15 m 50 ft Yes Blast Blast Blast Control Control Contr...

Page 61: ...mon Common Common Spare Spare Spare Parts Parts Parts Part Part Part Description Description Description 17D786 Hose restraint Whip check 17D787 Blast hose coupler pin kit 6 pack 17C124 Grommet hose coupler Fits either 1 0 in or 1 25 in dia hose 17L309 Gasket abrasive hose cam lock 10 pack 17L119 Gasket blast nozzle 5 pack 17L313 Blast circuit gasket kit 10 pack 26A093 Water tank filter w adapter ...

Page 62: ... 7 EQ1273 Natural 3 8 in OD 5 25 133 8 EQ1273 Natural 3 8 in OD 4 5 114 9 EQ1881 Natural 1 4 in OD 24 610 27 686 27 686 10 EQ1297 Red 3 8 in OD 10 5 267 13 5 343 13 5 343 11 EQ1297 Red 3 8 in OD 6 25 159 7 25 184 7 25 184 12 EQ1297 Red 3 8 in OD 18 75 476 27 686 27 686 13 EQ1882 Red 1 4 in OD 9 5 241 12 5 318 12 5 318 14 EQ1883 Blue 1 4 in OD 7 5 191 7 5 191 7 5 191 15 EQ1883 Blue 1 4 in OD 21 5 5...

Page 63: ...Dimensions Dimensions Dimensions Dimensions EQm EQm EQm Models Models Models EQs EQs EQs and and and EQs EQs EQs Elite Elite Elite Models Models Models 3A3489A 63 ...

Page 64: ...Dimensions EQs2 EQs2 EQs2 Elite Elite Elite Models Models Models EQc EQc EQc Models Models Models 64 3A3489A ...

Page 65: ...Dimensions EQ EQ EQ Trailer Trailer Trailer Models Models Models EQ200T EQ200T EQ200T EQ400T EQ400T EQ400T 3A3489A 65 ...

Page 66: ...hose connection 19 mm garden hose connection Abrasive capacity and wet weight was found using 80 grit garnet Using coarser media or less dense media will decrease weight Air Supply Hose Minimum ID 185 600 CFM compressor and less than 100 ft hose length 1 5 in ID 38 mm ID Over 600 CFM compressor or greater than 100 ft hose length 2 in ID 51 mm ID Sound Data Sound Pressure Level 133 dB A 133 dB A So...

Page 67: ...35 liters Abrasive capacity and wet weight was found using 80 grit garnet Using coarser media or less dense media will decrease weight Air Supply Hose Minimum ID 185 600 CFM compressor and less than 100 ft hose length 1 5 in ID 38 mm ID Over 600 CFM compressor or greater than 100 ft hose length 2 in ID 51 mm ID Sound Data Sound Pressure Level 133 dB A 133 dB A Sound Power Level 139 dB A 139 dB A I...

Page 68: ...ive capacity and wet weight was found using 80 grit garnet Using coarser media or less dense media will decrease weight Air Supply Hose Minimum ID 185 600 CFM compressor and less than 100 ft hose length 1 5 in ID 38 mm ID Over 600 CFM compressor or greater than 100 ft hose length 2 in ID 51 mm ID Sound Data Sound Pressure Level 133 dB A 133 dB A Sound Power Level 139 dB A 139 dB A Instantaneous So...

Page 69: ...m Maximum Recommended Pump Inlet Hose Length 5 ft 4 5 m Maximum Recommended Rise from Water Tank Outlet to Pump Inlet 16 in 41 cm Abrasive capacity and wet weight was found using 80 grit garnet Using coarser media or less dense media will decrease weight Air Supply Hose Minimum ID 185 600 CFM compressor and less than 100 ft hose length 1 5 in ID 38 mm ID Over 600 CFM compressor or greater than 100...

Page 70: ...nsumption 210 CFM 5 9 m 3 min Abrasive capacity and wet weight was found using 80 grit garnet Using coarser media or less dense media will decrease weight Trailer Connections Hitch Size 3 in Lunette Ring Pintel Eye Electrical Connector 7 way Flat Pin Sound Data Sound Pressure Level 133 dB A 133 dB A Sound Power Level 139 dB A 139 dB A Instantaneous Sound Pressure Level 131 dB C 131 dB C All readin...

Page 71: ...essure 175 psi 12 1 bar 1 21 MPa Dry Weight 7400 lb 3356 kg Wet Weight 9400 lb 4263 kg Air Capacity 425 CFM 12 m 3 min Abrasive capacity and wet weight was found using 80 grit garnet Using coarser media or less dense media will decrease weight Trailer Connections Hitch Size 3 in Lunette Ring Pintel Eye Electrical Connector 7 way Flat Pin Sound Data Sound Pressure Level 133 dB A 133 dB A Sound Powe...

Page 72: ...WARRANTY WARRANTY AND AND AND DISCLAIMS DISCLAIMS DISCLAIMS ALL ALL ALL IMPLIED IMPLIED IMPLIED WARRANTIES WARRANTIES WARRANTIES OF OF OF MERCHANTABILITY MERCHANTABILITY MERCHANTABILITY AND AND AND FITNESS FITNESS FITNESS FOR FOR FOR A A A PARTICULAR PARTICULAR PARTICULAR PURPOSE PURPOSE PURPOSE IN IN IN CONNECTION CONNECTION CONNECTION WITH WITH WITH ACCESSORIES ACCESSORIES ACCESSORIES EQUIPMENT ...