Repair
Repair
Repair
Replacing
Replacing
Replacing the
the
the DataTrak
DataTrak
DataTrak Battery
Battery
Battery
FIRE
FIRE
FIRE AND
AND
AND EXPLOSION
EXPLOSION
EXPLOSION HAZARD
HAZARD
HAZARD
To reduce the risk of fire and explosion, the battery
must be replaced in a non-hazardous location.
Use only an approved replacement battery (see
table). Use of an unapproved battery will void
Graco’s warranty.
Replace
Replace
Replace Battery
Battery
Battery
1.
Unscrew cable from the back of the reed switch
assembly.
2.
Remove the cable from the two cable clips.
3.
Remove the DataTrak module from the bracket.
Take the module and attached cable to a
non-hazardous location.
4.
Remove the two screws on the back of the
module to access the battery.
5.
Disconnect the used battery and replace it with
an approved battery.
Approved
Approved
Approved Batteries
Batteries
Batteries
Energizer® brand alkaline #522
Varta® brand alkaline #4922
UltraLife® brand lithium #U9VL
Duracell® brand alkaline #MN1604
30
3A3489A