4
306287
Installation
General Information
NOTE: Reference numbers and letters in parentheses
in the text refer to the callouts in the figures and the
parts drawing.
NOTE: Always use Genuine Graco Parts and Acces-
sories, available from your Graco distributor. If you
supply your own accessories, be sure they are ade-
quately sized and pressure rated for your system.
WARNING
To reduce the risk of serious injury, including fluid
injection, splashing in the eyes or on the skin, or
injury from moving parts:
1. Always relieve air and fluid pressure in the
pump before raising the elevator.
2. Keep your fingers and hands away from mov-
ing parts when raising or lowering the elevator
to prevent pinching or amputating them includ-
ing between the drum and pump mounting
assembly.
3. When the pump is in the raised elevator posi-
tion, do not leave it unattended. Keep air
supplied to the elevator. Block the pump, drum
cover or pump support bracket before working
on the pump.
4. Before working on the elevator, remove the
pump and relieve air pressure to the elevator.
Moveable Stand Mount Elevator
Locate the elevator where there is at least a 9 ft
(2.75 m) overhead clearance. Install the four
stabilizers (23) as shown in Fig. 1. Secure in place with
the setscrews (1).
Fixed Mount Elevator
Locate the elevator where there is at least 9 ft (2.75 m)
overhead clearance. Mark and drill holes for 0.5 in.
(13 mm) mounting bolts. See Fig. 2 and the dimen-
sional drawing on page 15. Level the base (17), using
shims if necessary. Secure the base to the floor using
four 1/2 in. (13 mm) mounting bolts which are long
enough to prevent the elevator from tipping.
Fig. 1
40
14 or 28
1
17 or 22
23
Fig. 2
Level
0.5” (13 mm) bolt
Shim
0.25”
(6.4 mm)
93.5”
(2375 mm)
Summary of Contents for 306287
Page 14: ...14 306287 Notes ...