background image

Parts 

22

3A0239F

Parts that Vary by HFR Module

Use the following table to locate parts that vary by module. See Parts Used on All HFR Modules, page 21, for parts 
used on all HFR modules.

Not shown.

--- Not for sale.

Ref.

Description

230V, 

1 phase, 

basic

230V, 

1 phase, 

loaded

230V, 

3 phase, 

basic

230V, 

3 phase, 

loaded

400V, 

3 phase, 

basic

4000V, 

3 phase, 

loaded

Qty.

8

SCREW, machine

103833(4)

103833(4)

103833(4)

103833(4)

103833(8)

103833(8)

-

18

SWITCH, disconnect

123969

123360

123969

123969

123969

123969

1

19

KNOB, operator disconnect

123967

123362

123967

123967

123967

123967

1

20

HARNESS, wire, MCM; 6/3

24C515

24C515

24C515

24C515

1

HARNESS, wire, MCM; 10/4

24C516

24C516

1

21

FILTER, 55A, 3P

123785

123785

1

23

HARNESS, wire, 8 awg, 
ground

24D216

24D216

1

35

CIRCUIT, breaker, 2P, 5A

123296 (1) 123296 (2) 123296 (1) 123296 (2) 123296 (1) 123296 (2)

-

36

CIRCUIT, breaker, 2P, 15A

123350

123350

123350

2

38

CIRCUIT, breaker, 2P, 40A

123455

123455

123455

4

39

CIRCUIT, breaker, 2P, 63A

123668

123668

123668

123668

1

40

CIRCUIT, breaker, 3P, 30A

123302

123302

1

41

BUSS BAR, 3P, 6 PIN, 115A

1

43

BUSS BAR, 3P, 18 PIN, 115A

1

44

BUSS BAR, 2P, 6 PIN, 115A

123310 (1)

123310 (3)

-

45

BUSS BAR, 2P, 12 PIN, 115A

123474

1

46

CONNECTOR, lug, power, 
115A

123306 (2) 123306 (3) 123306 (3)

123306 (8)

-

47

CAP, lug, power

---

1

48

SWITCH, disconnect, ph exp 
100A

123968

123968

1

56

HARNESS, wire 6 awg, 
14 awg

16A650

16A650

2

57

HARNESS, wire 6 awg

16A694 (3)

-

58

HARNESS, wire 4 awg, 
ferruled

24D221 (4)

24D221 (3)

24D221 (6)

-

59

HARNESS, wire, plug, tanks

24C517

24C517

24C517

2

62

HARNESS, wire, 6 awg, 
ferruled

16D536

16D536

2

72

LATCH, plug, 30A

24E823

24E823

24E823

2

Summary of Contents for 3A0239F

Page 1: ...l component proportioners For professional use only Not approved for use in European explosive atmosphere locations See page 3 for model information US Patent Pending Important Safety Instructions Rea...

Page 2: ...oting 5 Repair 6 Replace Power Supply 6 Replace Circuit Breaker 6 Electrical Schematics 7 Parts 20 HFR Power Distribution Modules 20 VRM Power Distribution Modules 23 VPM Power Distribution Modules 26...

Page 3: ...two configurations are not inter changeable Description Maximum Amperes Description HFR Power Distribution Modules 230V 1 Phase Basic 55 A 200 240VAC 1 phase 50 60 Hz 2 wire and PE 230V 1 Phase Fully...

Page 4: ...ns EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of drugs or alcohol Do not exceed the maximum working pressure or tempe...

Page 5: ...pply Defective power supply Check circuit breaker Check power supply Replace power supply No power to MCM heat zones or tanks Circuit breaker is tripping Check circuit breaker for tripping and defects...

Page 6: ...with nuts and washers 6 Connect power supply wires to the filter and the electrical enclosure connector 7 Close electrical enclosure door and turn on system power Replace Circuit Breaker 1 Turn off sy...

Page 7: ...Electrical Schematics 3A0239F 7 Electrical Schematics 230V 1 Phase Basic HFR Module Schematic...

Page 8: ...Electrical Schematics 8 3A0239F 230V 1 Phase Loaded HFR Module Schematic...

Page 9: ...Electrical Schematics 3A0239F 9 230V 3 Phase Basic HFR Module Schematic...

Page 10: ...Electrical Schematics 10 3A0239F 230V 3 Phase Basic VRM Module Schematic...

Page 11: ...Electrical Schematics 3A0239F 11 230V 3 Phase Loaded HFR Module Schematic...

Page 12: ...Electrical Schematics 12 3A0239F 230V 3 Phase Loaded VRM Module Schematic...

Page 13: ...Electrical Schematics 3A0239F 13 400V 3 Phase Basic HFR Module Schematic...

Page 14: ...Electrical Schematics 14 3A0239F 400V 3 Phase Basic VRM Module Schematic...

Page 15: ...Electrical Schematics 3A0239F 15 400V 3 Phase Loaded HFR Module Schematic...

Page 16: ...Electrical Schematics 16 3A0239F 400V 3 Phase Loaded VRM Module Schematic...

Page 17: ...138 136 134 132 130 128 126 124 122 120 118 114 116 112 108 106 104 102 100 141 148 144 146 143 111 139 137 135 133 131 129 127 125 123 121 119 115 117 113 109 107 105 103 101 50 60HZ 3PH 230V DISC 1...

Page 18: ...36 134 132 130 128 126 124 122 120 118 114 116 112 108 106 104 102 100 141 148 144 146 143 111 139 137 135 133 131 129 127 125 123 121 119 115 117 113 109 107 105 103 101 151 50 60HZ 3PH 400V DISC 1 L...

Page 19: ...134 132 130 128 126 124 122 120 118 114 116 112 108 106 104 102 100 141 148 144 146 143 111 139 137 135 133 131 129 127 125 123 121 119 115 117 113 109 107 105 103 101 151 50 60HZ 3PH 400V DISC 1 L3 1...

Page 20: ...ion Modules r_24C686_3A0239_2b 400V 3 Phase Basic Module Shown r_24C688_3A0239_4a Circuit Breaker Detail for 400V 3 Phase Loaded Module 19 18 48 56 4 11 8 5 6 9 7 3 1 2 8 3 13 12 39 35 10 21 56 62 14...

Page 21: ...666 TERMINAL ground 1 5 113783 SCREW mach pan hd 1 6 100985 WASHER lock ext 1 7 16A647 RAIL din 17 7 in 1 9 16A649 HARNESS ground wire 8 awg 1 10 123363 BLOCK terminal ground 10mm 4 11 LABEL identific...

Page 22: ...23785 1 23 HARNESS wire 8 awg ground 24D216 24D216 1 35 CIRCUIT breaker 2P 5A 123296 1 123296 2 123296 1 123296 2 123296 1 123296 2 36 CIRCUIT breaker 2P 15A 123350 123350 123350 2 38 CIRCUIT breaker...

Page 23: ...400V 3 Phase Basic Module Shown r_24C687_3A0239_3a r_24C689_3A0239_7a Circuit Breaker Detail for 400V 3 Phase Loaded Module 19 18 48 56 4 11 8 5 6 23 7 3 1 2 8 3 13 12 39 35 10 21 56 57 14 23 7 10 44...

Page 24: ...1 7 16A647 RAIL din 17 7 in 1 9 16A649 HARNESS ground wire 8 awg 1 10 123363 BLOCK terminal ground 10mm 4 11 LABEL identification 1 12 24D217 HARNESS wire 16 awg ferrule 2 13 24D218 HARNESS wire 16 a...

Page 25: ...round 24D216 24D216 2 36 CIRCUIT breaker 2P 15A 123350 123350 2 38 CIRCUIT breaker 2P 40A 123455 123455 4 39 CIRCUIT breaker 2P 63A 123668 123668 2 40 CIRCUIT breaker 3P 30A 123302 123302 2 42 BUSS BA...

Page 26: ...stribution Modules 400V 3 Phase Basic Module Shown Circuit Breaker Detail for 400V 3 Phase Loaded Module 23 46 7 10 47 39 35 44 37 36 35 39 18 48 19 57 55 49 50 8 23 62 3 8 21 9 57 8 3 12 13 2 4 5 6 8...

Page 27: ...Parts 3A0239F 27 ti18048a 25 26 29 61 28 27 24 71 71 20 70 70 1b 1c 1a...

Page 28: ...25 123589 BUSHING wire protector snap in 4 26 111800 SCREW cap hex hd 10 27 123679 BUSHING wire protector snap in 6 28 123398 PLUG hole 1 1 2 diameter 6 29 123590 PLUG hole 2 in diameter 4 35 123296 C...

Page 29: ...Parts 3A0239F 29...

Page 30: ...of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANT...

Reviews: