13
307–452
Service
Installing Fluid and Air Fittings
If the fluid fitting (22) is removed, be sure to install its
gasket and washer when reinstalling the fitting. Apply
Loctite
r
242 sealant or equivalent on the fluid fitting
threads and torque it into the gun body to 20 ft-lb
(27 N
S
m).
If the air fitting (23) is removed, apply Loctite
r
PST
pipe sealant or equivalent to its threads and screw it
into the gun body.
Fig. 3
6
7
11
13
12
9
1
10
22
DETAIL D
4
5
5
23
6
2
1
3
1
Apply Loctite
r
242 sealant or equivalent on
threads and torque to 20 ft-lb (27 N.m).
2
See Detail D.
5
3
Turn counterclockwise to widen spray pattern.
Turn clockwise to narrow spray pattern.
4
Turn counterclockwise to increase fluid output.
Turn clockwise to decrease fluid output.
Apply Loctite
r
PST pipe sealant or equivalent on threads.
Lubricate daily with light oil.
6