6
308455
Setup
III.
Unpack the system.
1.
In addition to the assembled unit, these compo-
nents are packed loosely or separately: hose set,
gun, instruction manuals. These are the manuals
you should receive:
308369
Pressure pot
308167
Air regulator
312414
HVLP spray gun (Model 237413)
312414
Air spray gun (Model 237409)
IV.
Connect the hose set and gun to the
system.
See Fig. 1, on page 5.
1.
Connect the air hose (43) between the gun air
shutoff valve (17a) and the air inlet of the spray
gun. These are 1/4–18 npsm swivel fittings.
2.
Connect the fluid hose (40) between the fluid
shutoff valve (18) and the fluid inlet of the spray
gun. These are 3/8–18 npsm swivel fittings.
3.
Verify that all fittings throughout the system are
tightened securely.
V.
Ground the system.
WARNING
FIRE AND EXPLOSION HAZARD
To reduce the risk of static sparking,
ground the pressure pot and all other
equipment used or located in the spray
area. Check your local electrical code for
detailed grounding instructions for your
area and type of equipment. Also read
FIRE AND EXPLOSION HAZARD on
page 2.
Ground all of this equipment:
1.
Pressure pot: One end of the ground wire (13) is
already connected to the pressure pot. Connect
the other end of the ground wire to a true earth
ground.
2.
Air compressor: Ground according to manufac-
turer’s recommendations.
3.
Object being sprayed: Ground according to local
code.
4.
Fluid supply container: Ground according to
local code.
5.
All solvent pails used when flushing: Ground
according to local code. Use only metal pails,
which are conductive. Do not place the pail on a
non-conductive surface, such as paper or card-
board, which interrupts the grounding continuity.
Summary of Contents for AirPro 308455K
Page 16: ...16 308455 Notes ...