Operation
3A4442F
19
ProGuard Error Codes
This sprayer protects itself against high and low voltage. One of three error codes is displayed
if the supply voltage is out of range.
Digital Tracking System
(DTS)
Operation Main Menu
Short press to move to next display. Press
and hold (5 seconds) to change units or reset
data.
1.
Turn pressure to lowest setting. Trigger
gun to relieve pressure. Turn prime valve
down to DRAIN position.
2.
Turn ON/OFF switch to the
ON
position.
Pressure display appears. Dashes will
not appear unless pressure is less than
200 psi (14 bar, 1,4 MPa).
Error Code
Definition
Multiple incoming voltage surges detected - unplug sprayer
and locate good voltage supply to prevent damage to
electronics.
Typical cause of this error is plugging into a circuit that is higher than
the rated voltage of the sprayer. Find a circuit that supplies the
correct voltage.
Incoming voltage too low for sprayer operation - unplug
sprayer and locate good voltage supply to prevent damage to
electronics.
Typical cause of this error is other equipment on the same circuit or
generator frequently turning on/off under load. Find a circuit that is
dedicated to the sprayer.
Sprayer plugged into wrong voltage - unplug sprayer and
locate correct voltage supply.
Typical cause of this error is a GFCI box that is wired for the wrong
voltage (240V vs. 120V). No damage has occurred to the sprayer.
Find a circuit with the correct voltage and the sprayer will run
correctly.