Troubleshooting
30
309550ZAP
Troubleshooting
1. Follow the
before checking or repairing the gun.
2. Check all possible problems and causes before
disassembling the gun.
NOTICE
To prevent cross-contamination in the gun, do not
interchange A component (isocyanate) and B
component (resin) parts. Cross-contamination can
result in cured material in the gun. Cured material may
damage the sealing surfaces, block fluid passages,
and prevent gun function.
Problem
Cause
Solution
Gun does not fully actuate when
triggered
The safety lock is engaged.
Disengage safety lock. See
The muffler is plugged (22).
Clean the muffler. See
The air valve o-rings are damaged
(24).
Replace the air valve o-rings. See
Fluid does not spray when the gun is
fully actuated
The fluid valves are closed (12b).
Open the fluid valves.
The impingement ports are plugged. Clean the impingement ports. See
The check valves are plugged (26).
Clean the check valves. See
Gun actuates slowly
The muffler is plugged (22).
Clean the muffler. See
The piston o-rings are damaged (16,
17).
Replace the piston o-rings. See
The air valve is dirty, or the o-rings
are damaged (24).
Clean air valve or replace o-rings.
See
Gun delays, then actuates abruptly
The material around side seals is
cured (18).
Inspect side seals (18c) and mix
chamber (19) for scratches. Replace.
See
The retaining ring (9) is not bottomed
out.
Tighten retaining ring until bottomed
out.
Loss of round pattern
The mix chamber nozzle is dirty.
Clean the mix chamber nozzle. See
page