Troubleshooting
309550ZAP
31
Loss of flat pattern
The spray tip is plugged.
Clean in compatible solvent. See
Reposition or Replace Flat Spray
Tips
The tip is worn.
Replace the flat spray tip. See
Reposition or Replace Flat Spray
Tips
The mix chamber nozzle is dirty.
Clean the mix chamber nozzle. See
page
Leakage between flat tip and mix
chamber
The tip is not seated properly.
Reassemble. See
The o-ring is damaged or missing
(40).
Replace the flat spray tip o-ring. See
Reposition or Replace Flat Spray
Tips
Pressure imbalance
The impingement ports are plugged. Clean the impingement ports. See
The check valves are plugged (26).
Clean the check valves. See
The viscosities not equal.
Adjust temperature to compensate.
A and/or B fluid in gun air section
The side seals are damaged (18c).
Replace. See
Chamber and Side Seal
Cartridges
The mix chamber is damaged(19).
Replace. See
Chamber and Side Seal
Cartridges
The side seal o-rings are damaged
(18d, 18e).
Replace the side seal o-rings. See
Inspect the Mix Chamber and Side
Seal Cartridges
The air cap is tightened while the
fluid valves (12b) are open.
Close valves first.
Fluid mist from mix chamber or air
cap
The side seals (18c) are damaged.
Replace the side seals. See
the Mix Chamber and Side Seal
Cartridges
The side seal o-rings (18d, 18e) are
damaged.
Replace the side seal o-rings. See
Inspect the Mix Chamber and Side
Seal Cartridges
The mix chamber (19) is damaged.
Replace the mix chamber. See
Inspect the Mix Chamber and Side
Seal Cartridges
Excessive overspray
Too much cleanoff air.
,
Problem
Cause
Solution