Operation
20
309550ZAP
Piston Safety Lock
To engage the piston safety lock:
Push knob in and
turn clockwise. If engaged, gun will not actuate.
To disengage the piston safety lock:
Push knob in
and turn counterclockwise until it pops out. There will be
a gap between knob and gun body.
Turn the Air Cap
Always follow the
before turning the air cap (C).
Loss of Air Pressure
In event of loss of air pressure, gun will continue to
spray. To shut off gun, do one of the following:
•
Engage the piston safety lock. See
•
Close fluid valves A and B.
Flush Gun
1. Follow the
2. Disconnect the gun from the hose.
3. Connect the gun to the flush manifold block (52).
4. Flush with compatible solvent into a grounded metal
pail, holding a part of fluid manifold (M) firmly to side
of pail. Use the lowest possible fluid pressure when
flushing.
5. Follow the
6. Disconnect the gun from the flush manifold block.
NOTE:
For a more thorough flush, Solvent Flush Kits
248139 and 248229 are available as an accessory. The
kits connect to Flush Manifold 15B817. See your
Solvent Flush Kit manual for detailed flushing
instructions.
High-pressure fluid from dispensing devices can
pierce skin. To help prevent serious injury from
pressurized fluid, always engage the piston safety
lock and close the material shutoff valves to avoid
accidental triggering whenever you stop spraying.
Engaged
r_257826_313266_1_2b
Disengaged
r_257826_313266_1_1b
C
B
TI2421A
To avoid fire and explosion, always ground equipment
and waste container. To avoid static sparking and
injury from splashing, always flush at the lowest
possible pressure.
B
A
TI2421A