Setup
313516F
15
Flush Spray Gun
Before running any paint through the spray
gun:
1. Flush the gun with a solvent that is compat-
ible with the fluid to be sprayed, using the
lowest possible fluid pressure and a
grounded metal container.
2. Perform Pressure Relief Procedure; see
page 18.
Position Air Cap
Air caps are factory-set with the alignment pin
(A) set to a vertical spray pattern. To change
the air cap to a horizontal spray pattern, use a
1/6 in. hex wrench to unscrew the alignment
pin (A) and relocate it to the horizontal spray
pattern hole. When relocating the pin use low
strength thread locker. Torque to 1.5-2.5 in-lb
(0.2-0.3 N•m).
Do not overtighten
. Refer to
F
IG
. 8: Manifold Ports
FAN
ATOM
CYL
KEY
N Cylinder Air Inlet: accepts 1/4 in. (6.3 mm) O.D. tubing
P Atomization Air Inlet: 3/8 in, (9.5 mm) O.D. tubing
R Fan Air Inlet: 3/8 in. (9.5 mm) O.D. tubing
S Fluid Inlet: 1/4 npsm
T Fluid Outlet (circulating gun only): 1/4 npsm
N
S (or T)
T (or S)
R
P
N
S (or T)
T (or S)
R
P
ti8096a
ti8097a
Side Mounted Manifold Ports
Bottom Mounted Manifold Ports
FAN
ATOM
CYL
F
IG
. 9: Position Air Cap
Vertical Pattern
Horizontal Pattern
ti8171a
ti8170a
A
ti8172a