background image

 

PERIODIC MAINTENANCE 

 

ASSEMBLY 

 
Refer to the illustration above and the drawings in the back of this manual for your exact model. 

 

Note:

  Clean all valve parts with an appropriate solvent prior to reassembly.  Always install new, lubricated       

O-rings and seals when assembling the valve.  Use Krytox 203GPL (part number 84/0200-K3/11) for lubricating 
valve parts including seals and o-rings.  Apply a very thin film of lubricant to the inside diameter surfaces of the 
Top Cylinder Block (17), the outside of the Metering Rod (21) and to the seals and o-rings.  Check the Metering 
Rod/Sleeve Assembly (7) for wear and if it is worn secure a replacement before proceeding. 
 

Note:

  Use caution as you install new U-cup and Posipak seals so that they are not pinched or torn. Do this by 

making sure they are lubricated, and by tucking the lips of the seal inward before uniformly pushing them into 
position. 
 
1.  Insert the lubricated Posipak Seal (14) lip side down into the Metering Rod Sleeve (7). 
2.  Insert the Seal Separator Block (5). 
3.  Install, in order, the lubricated Posipak Seal (20) lip side up, the lower Washer (16), and the lower Retaining 

Ring (3).   

4.  Install the Seal Separator Rod (6), aligning the cross-hole so that the metering rod can pass through it. 
5.  Insert the Metering Rod (21) carefully through the lower Retaining Ring (3), the lower Washer (16), the 

Posipak Seal (20), the Seal Separator Block (5), Seal Separator Rod (6) and the Posipak Seal  (14).   

6.  Install the lubricated U-cup Seal (15) lip side down into the Top Cylinder Block (17). 
7.  Install the upper Washer (16), then the upper Retaining Ring (3). 
8.  Install the lubricated O-ring (4) on the Piston (2). 
9.  Install the lubricated O-ring (19) into the Top Cylinder Block (17). 
10.  Insert the Piston (2) with O-ring (4) part way into the Top Cylinder Block (17) carefully so that the piston 

threads do not damage the Posipak Seal (14).  Position the piston to accept the head of the metering rod. 

11.  Insert the Metering Rod head (21) into the Piston (2). 
12.  Screw the Metering Rod/Sleeve Assembly (7) into the Top Cylinder Block (17).   
13.  Install the lubricated O-ring (9) on the Metering Rod/Sleeve Assembly (7).   
14.  Install the lubricated O-ring (12) carefully over the threads of the Needle Adapter (10).   

Note:If the valve has the alternate needle adapter, install the outside O-ring (22). 

15.  Insert the lubricated O-ring (8) into the Metering Rod/Sleeve Assembly (7). Use a blunt tool to seat the o-ring 

firmly. 
Note:  For .188 diameter rod models, first insert the Plastic Washer (8A) into the Metering Rod/Sleeve 
Assembly (7), followed by the O-ring (8).  Then, use a blunt tool to seat the o-ring and washer firmly. 

16.  Insert the Check Valve Poppet (13) into the Check Valve Spring (11).  Insert the check valve poppet/spring 

assembly into the Needle Adapter (10). 

17.  Screw the needle adapter/check valve spring/poppet assembly firmly into the Metering Rod/Sleeve   

Assembly (7). 

18.  Screw on the Stroke Adjustment Collar (1). 
19.  Tighten the Socket Head Set Screw (18). 
20.  Mount the valve and connect the air lines.  If your valve is equipped with optional cycle detection, install the 

sensors and tighten the set screws. 

 
The model 1206 Dispense Valve is now ready to be placed back into service. 
 
 
 
 
 
 
 
 

Page 8 

Summary of Contents for DISPENSIT 1206

Page 1: ...Instructions Dispensit 1206 332091A EN Dispense Valve Important Safety Instructions Read all warnings and instructions in this manual Save these instructions ...

Page 2: ...e Valve 4 Air Controller 4 Operating Procedures 5 Dry System Checkout 5 Wet System Checkout 5 Operation Adjustments 6 Periodic Maintenance 6 Dispensing Needle 6 Disassembly 6 Model 1206 General Illustration 7 Assembly 8 Troubleshooting 9 Model 1206 Recommended Spare Parts 10 Accessories 11 General Accessories 11 Model 1206 Accessories 11 General Guidelines for O rings and U cup Seals 12 Warranty 1...

Page 3: ...si 6 9 bar air pressure to the dispense valve Do not exceed 100 psi 6 9 bar material inlet pressure to the dispense valve higher pressures may cause a hazard or serious injury Note The recommended pneumatic operating system pressure is 70 psi 4 8 bar clean dry air if your system uses a syringe feed do not exceed 60psi 4 1 bar air pressure to the syringe inlet Toxicity and flammability hazards depe...

Page 4: ...owing the metering rod to rise when the rod passes the inlet material is pushed in to fill the dispense cavity The system is again in the normal ready state SETUP PROCEDURE MOUNTING DISPENSE VALVE The1206 dispense valve can be mounted in a variety of ways Consult the factory for an application review AIR CONTROLLER Operation of the 1206 requires a controller that provides the following A minimum o...

Page 5: ...ng required for the application Begin with material pressure set at 15 psi 1 0 bar and gradually increase material pressure until material feeds through the valve Note When utilizing a remote reservoir the reservoir delivery tubing and fittings must be compatible with the material being dispensed and capable of withstanding the dispensing pressure WARNING Do not apply air pressure to the Dispense ...

Page 6: ...e if damaged or clogged Replacement needles can be ordered for the Model 1206 Dispense Valve by specifying the proper part number seen in the Recommended Spare Parts section in this manual DISASSEMBLY Refer to the illustration below and the drawings for your exact model at the back of this manual WARNING When disassembling multiple valves do not mix parts Metering rods are matched with their sleev...

Page 7: ...eal 4 O Ring 15 U cup Seal 5 Seal Separator Block 16 Washer 6 Seal Separator Rod 17 Top Cylinder Block 7 Metering Rod Sleeve Assembly 18 Socket Head Set Screw 8 O Ring 19 O Ring 8A Plastic Washer 188 rod models 20 Posipak Seal 9 O Ring 21 Metering Rod 10 Needle Adapter 22 O Ring some models 11 Check Valve Spring ALTERNATE NEEDLE ADAPTER ...

Page 8: ...o the Top Cylinder Block 17 7 Install the upper Washer 16 then the upper Retaining Ring 3 8 Install the lubricated O ring 4 on the Piston 2 9 Install the lubricated O ring 19 into the Top Cylinder Block 17 10 Insert the Piston 2 with O ring 4 part way into the Top Cylinder Block 17 carefully so that the piston threads do not damage the Posipak Seal 14 Position the piston to accept the head of the ...

Page 9: ... any air trapped in it A second cause could possibly be that the material is not filling the metering rod chamber fully and in time Check the reservoir pressure it may be too low for the type of material being dispensed and or the cycle time may be too fast Cycle time is a function of the air supply controller To adjust follow the directions found in the controller operating manual SLOW OR SLUGGIS...

Page 10: ...nt Needles for Single Needle Block Models Needle length shown is length projecting from LL hub Other lengths available Quantity Description Needle Part Number Needle Sampler Package 10 each of 14 16 18 20 and 22 E4000025 50 Needle LL 14 ga x Pack of 50 E4000001 50 Needle LL 14 ga x 1 Pack of 50 E4000014 50 Needle LL 15 ga x Pack of 50 E4000004 50 Needle LL 16 ga x Pack of 50 E4000088 50 Needle LL ...

Page 11: ... Consult your Dispensit dealer or the factory for details MODEL 1206 ACCESSORIES Cycle Detection The cycle detection option for the 1206 lets your controller act upon detection of valve stroke cycle completion by use of a fiber optic sensor Item Description A5010014 Cycle Detection PNP sensor type A5010042 Cycle Detection NPN sensor type On Board Syringe Feed Assemblies Syringe feed assemblies can...

Page 12: ...it may not return to the proper size Do not use any sharp tools or objects to install O rings U cup Seal Guidelines Always replace a U cup seal with the identical one in size durometer hardness type and material of construction Always be alert to the location and size of each U cup seal as many look alike and be careful not to mix them Often similar sizes may be used in various locations on the eq...

Page 13: ......

Page 14: ...will be made at a reasonable charge which charges may include the costs of parts labor and transportation Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or cons...

Reviews: