308357
21
Technical Data
(MODEL 236932 PREMIER PUMP)
Category
Data
Ratio
74:1
Maximum fluid working pressure
500 bar (7252 psi)
Maximum air input pressure
6.7 bar (97 psi)
Pump cycles per 3.8 liters (1 gal.)
14
Maximum flow at 60 cycles/min.
15.9 liters/min (4.2 gpm)
Air motor piston effective area
800 cm
@
(124 in.
@
)
Stroke length
120 mm (4.75 in.)
Displacement pump effective area
11 cm
@
(2.79 in.
@
)
Maximum pump operating temperature
(ambient and fluid)
82
_
C (180
_
F)
Air inlet size
3/4 npsm(f)
Fluid inlet size
2 in. npt(f)
Fluid outlet size
1 in. npt(f)
Weight
approx. 109 kg (240 lb)
Wetted parts
Carbon Steel; Chrome Steel, Zinc and Nickel Plating;
440 and 17–4 PH Grades of Stainless Steel;
Alloy Steel; Tungsten Carbide; Ductile Iron; PTFE;
Glass-Filled PTFE; Leather
Sound Pressure Levels (dBa)
(measured at 1 meter from unit)
Input Air Pressures at 15 cycles per minute
Air Motor
0.28 MPa, 2.8 bar
(40 psi)
0.48 MPa, 4.8 bar
(70 psi)
0.63 MPa, 6.3 bar
(90 psi)
0.7 MPa, 7 bar
(100 psi)
Premier
82.5
82.4
83.2
83.0
Sound Power Levels (dBa)
(tested in accordance with ISO 9614–2)
Input Air Pressures at 15 cycles per minute
Air Motor
0.28 MPa, 2.8 bar
(40 psi)
0.48 MPa, 4.8 bar
(70 psi)
0.63 MPa, 6.3 bar
(90 psi)
0.7 MPa, 7 bar
(100 psi)
Premier
90.6
90.6
93.0
95.9
Summary of Contents for Dura-Flo 1100