Repair
3A7467C
37
Replace the DataTrak Fuse
Replace Fuse
1. Remove the screw, metal strap, and plastic holder.
2. Pull the fuse away from the board.
3. Replace with an approved fuse.
To reduce the risk of fire and explosion, the fuse
must be replaced in a non-hazardous location.
Use only an approved replacement fuse (see table).
Use of an unapproved fuse will void Graco's
warranty.
Approved Fuses
DataTrak Part
Number
Series Letter
Fuse Required
17K057
A or B
24C580
C and later
24V216
All other part
numbers
A
24C580
B and later
24V216
Fuse
ti11994b