1
Assemble valve (17) with plunger facing the
bent manifold (16).
2
Apply anti-seize to threads on clamp (62).
Align the nuts pointing towards the front of
the enclosure. Torque nuts to 85 +/- 5 in-lb
(9.6 +/- 0.5 N•m).
3
Apply anti-seize to threads on clamp (60).
Align the nuts pointing towards the front of
the enclosure. Torque nuts to 15 +/- 2 ft-lb
(20.3 +/- 2.7 N•m).