SETUP 

Fig  1 

WARNING 

DO  NOT  connect  a 

spray  hose  to  this 

valve.  This  is  only  a 

manual 

pressure 

relieving  device. 

1.

Check  Hydraulic  Fluid 

( Refer to Fig  1.)

a. Push  in  on  the  two  spring  clips  and  lift  the

shield off of the sprayer.

b.  Remove  the  expander  plug  from  the  sump  fill

hole  and  lift  strainer/dipstick  out  of  the  hole.

Using a 

clean,  lint-free 

cloth,  wipe the dipstick

clean,  replace it in the sump hole,  then remove

it  and  check  the  fluid  level.  The  fluid  level

should be between  the ADD and FULL  marks

on the dipstick.

c. If the  fluid  level is at or below the ADD mark,

replace  the  strainer/dipstick  in  the  sump  hole

and  add  approved hydraulic fluid  through  the

hole as necessary to bring the level to the FULL

mark. See Accessories on page 19 for approved

hydraulic  fluid.  1-3/4  pints  will  raise  the  level

from ADD to FULL.

2. Connect  Hose and  Gun (Refer to Fig  U

a. Remove  the  plastic  cap  plug  from  the  filter

outlet nipple and tightly screw the 50 ft ( 15.2 m)

fluid hose onto the nipple.

b. Tightly  connect  the  whip  hose  between  the

fluid hose and the gun inlet connection.

c. Don't use thread sealant,  and  don't install the

spray tip yet!

3.

Fill 

Packing  Nut/Wet-Cup 

(See Fig  1.)

a.  Push in on the two spring  clips and remove  the 

sprayer shield.

b. Fill the packing nut/wet-cup 1 /3 full with Grace

Throat  Seal  Liquid  (TSU,  supplied.  Install  the 

sprayer  shield.

-------WARNING------­

N EVER operate  the sprayer without the shield  in­

stalled.  The  shield  .encloses  the  fan  and  other 

moving  parts  which  can  cause  serious  bodily  in­

jury,  including  amputation.  The  shield  also  con­

tains important 

WARNING 

information. 

Operating  the  sprayer without the  shield  in  place 

may cause it to overheat. 

306-941 

4. Check  Electrical  Service

a. Be  sure  the  electrical  service  is  120  V,

60  HzAC,  15  Amp  (minimum)  and  that  the

outlet  you use is properly grounded.

NOTE: 

licensed electrician can rewire the sprayer 

for  230  volt  service  if  necessary.  See  page 

15. 

b. Use an extension cord which has 3  wires  of a

minimum  12  gauge  size,  and  a  maximum  of

50  ft  ( 15  m)  long.  Longer  lengths  may  affect

sprayer performance.

5. Plug  in the  Sprayer

a. Be  sure  the  ON/OFF switch is  OFF.  Refer  to

Fig  1. Then plug the cord into a grounded elec­

trical  outlet at least 20 ft  (6 m)  away  from the

spray area .

.--------WARNING------­

Proper  electrical  grounding is essential  to  reduce 

the 

risk 

of  fire  or  explosion  which  can  result  in 

serious bodily injury and property damage. Refer 

to  the  warning  section  GROUNDING  on  page  3 

for more detailed grounding instructions. 

6.

Flush  the  pump 

to  remove  the  lightweight  oil

which  was  left  in  to  protect  pump  parts  after  fac­

tory  testing. 

See  "Flushing  Guidelines" 

on  page 9

for flushing procedure.

7.

Prepare the paint 

according to the manufacturer's

recommendations.

a. Remove any skin  that may have formed.

b. Stir the paint to dissolve hard pigments.

c. Strain  the paint through a fine nylon  mesh bag

(available at most paint dealers)  to remove par­

ticles that could clog the filter or spray tip. 

This

is  probably  the  most  important  step  toward

trouble-free spray  painting.

Summary of Contents for EH 333 HYDRA-SPRAY 226-333

Page 1: ... Servicing Pump 13 Assembling Pump 13 Replacing the Electric Motor 14 Replacing the Hydraulic Pump 14 Electric Motor Wiring Diagram 15 Parts Drawing 16 17 Parts List 18 How to Order Replacement Parts 19 Accessories 19 Technical Data Back Cover Warranty Back Cover ORACO MODEL 226 333 SHOWN 306 941 Rev S SUPERSEDES R WARNING Hazard of Using Fluids Containing Halogenated Hydrocarbons Never use 1 1 1 ...

Page 2: ...pray and reduces the risk of fluid injection when the tip is not installed Check diffuser operation regularly Follow the Pressure Relief Procedure below then remove the spray tip Aim the gun into a metal pail holding the gun firmly to the pail Using the lowest possible pressure trigger the gun If the fluid emitted is not diffused in to an irregular stream replace the diffuser immediately Tip Guard...

Page 3: ...lso read FIRE OR EXPLOSION HAZARD FIRE OR EXPLOSION HAZARD Static electricity is created by the flow of fluid through the pump and hose If every part of the spray equipment is not properly grounded sparking may occur and the system may become hazardous Sparking may also occur when plugging in or unplugging a power supply cord Sparks can ignite fumes from solvents and the fluid being sprayed dust p...

Page 4: ...age n est pas en place Verifier le fonctionnement du diffuseur regulierement Pour cette verification detendre la pression en observant la Marche a Suivre pour Detendre la Pression donnee plus loin puis enlever l ajutage du pulverisateur Pointer le pistolet dans un seau en metal en le maintenant fermement centre le seau Puis en utilisant la pression la plus faible possible ap puyer sur la gachette ...

Page 5: ...ait la pulverisation Ne pas brancher au debrancher un cordon d alimentation quel qu il soit dans la zone au se fait la pulverisation quand ii y a le moindre risque que des vapeurs encore presentes dans l air prennent feu Mise a la terre ou a la masse Pour reduire les risques de production d etincelles d electricite statique le pulverisateur et tous les equipements utilises au se trouvant dans la z...

Page 6: ...tola Difusor El difusor de la pistola dispersa el chorro pulverizado y reduce el riesgo de inyecci6n cuando no esta instalada la boquilla Revisar con regularidad el funcionamiento del difusor Seguir el procedimiento de descarga de presi6n dado mas abajo y despues sacar la boquilla Apuntar la pistola a un balde metalico sosteniendola bien firme contra el Utilizando la presi6n mas bajo posible dispa...

Page 7: ...n la puesta a tierra en malas condiciones Leer tambien la infor maci6n sobre RIESGO DE INCENDIO O EXPLOSION mas arriba PELIGRO DE INCEND O 0 EXPLOSION El flujo a alta velocidad del fluido al pasar por la bomba y manguera crea electricidad estatica Si todas las partes del equipo pulverizador no tienen buena tierra pueden ocurrir chispas convirtiendo al sistema en algo peligroso Tambien pueden produ...

Page 8: ...talled The shield encloses the fan and other moving parts which can cause serious bodily in jury including amputation The shield also con tains important WARNING information Operating the sprayer without the shield in place may cause it to overheat 8 306 941 4 Check Electrical Service a Be sure the electrical service is 120 V 60 HzAC 15 Amp minimum and that the outlet you use is properly grounded ...

Page 9: ...shing and static spark ing which can cause fire or explosion With the 5 Storage Water base paint flush with water then mineral spirits and leave the pump hose and gun filled with mineral spirits Shutoff and unplug the sprayer open the drain valve to relieve pressure and leave open Oil base paint flush with mineral spirits Shutoff and unplug the sprayer open the drain valve to relieve pressure and ...

Page 10: ...n the ON OFF switch to ON and slowly increase the pressure setting until the sprayer starts Keep the gun triggered until all air is forced out of the system and the paint flows freely from the gun Release the trigger and engage the safety NOTE If the pump is hard to prime place a con tainer under the drain valve and open it When fluid comes from the valve close it Then disengage the gun safety and...

Page 11: ...eck the wet cup every eight hours to prevent overflow 2 Clean the fluid filter often and whenever the sprayer is stored First follow the Pressure Relief Procedure Warning on page 10 Refer to manual 307 273 supplied for the cleaning procedure 3 Flush the sprayer at the end of each work day and fill it with mineral spirits to help prevent pump corrosion and freezing See Flushing Guidelines on page 9...

Page 12: ...tric motor stops while spraying Electric motor runs but paint pump won t work Paint pump runs but output low on up stroke down stroke both strokes Excessive leakage around hydraulic CAUSE motor piston rod wiper Paint leaks into wet cup Excessive surge at spray gun Not enough paint breakup Paint coating too thick Tails or fingers in spray pattern Spitting from spray gun Static sparking from spray g...

Page 13: ...all packing retainer glands and packings See Fig 9 Put parts in solvent to soak Screw packing nut out of housing and remove throat packings and glands See Fig 9 Clean all parts thoroughly with solvent and carefully in spect for damage or wear Inspect the outer surface of the displacement rod and the inner surface of the insert sleeve in the housing for scratches or scoring which could damage the p...

Page 14: ...ll parts on new motor When reassembl ing nipple be sure to engage threads at least five full turns Carefully put the new motor through coils force it into support mounting and screw the mounting bolts in tightly See Fig 11 Set the gap between the two coupling halves at 0 31 in 0 8 mm then tighten setscrew firmly See Fig 11 Clean sump of sediment and reassemble unit using a new sump gasket Pour hyd...

Page 15: ...ring Diagram NOTE The sprayer is wired for 115 volt service A licensed electrician can rewire it for 230 volt service if necessary FROM MOTOR FOR 115V SERVICE FROM MOTOR 4 J IN_SULATE 9 FOR230V SERVICE Fig 13 306 941 15 ...

Page 16: ...135 tJ Displacement Pump Repair Kit Must be ordered separately Ref No _ 2 5 gal 19 liter Suction Tube Assy 218 136 with leather packings Consists of Ref No Oty 12 1 13 1 14 1 15 3 16 1 19 1 20 1 21 3 22 1 23 1 24 1 26 1 66 1 218 136 with PTFE packings Consists of Ref No Oty 12 1 13 1 14 1 16 1 20 1 22 1 23 4 __ 24 _ 4 Torque to 55 75 ft lb 75 96 N r11J 147 1 Torque into hydraulic motor 15 25 ft lb...

Page 17: ...Ref No 33 Shield Assy Includes items 34 40 39 44 80 Sugge ted Replacement Parts 306 941 17 ...

Page 18: ...ring PTFE RETAINER a ring SLEEVE housing GUIDE ball FRAME cart HANDLE cart SUPPORT motor pump SHIELD sprayer includes items 34 40 RIVET blind 1 8 dia CLIP spring tension PLUG LABEL instruction LABEL instruction 1 113 210 659 BALL VALVE see 306 861 for parts 1 39 176 375 LABEL warning 1 114 167 907 KNOB valve adjustment 1 40 176 115 SHIELD bare 1 116 214 911 PANEL enclosure air 1 44 208 914 GUARD f...

Page 19: ...used where one tip does not provide sufficiently ti wide spray pattern or work piece demands two spray patterns angled in opposite directions STATIC FREE FLUID HOSE Nylon 3000psi 210 bar MAXIMUM WORKING PRESSURE Part No ID Length Thd Size 214 701 3 16 4 8 mm 3 ft 914 mm 1 4 npt mxf 210 540 1 4 6 4 mm 26 ft 7 6 ml 1 4 npsm f 210 541 1 4 6 4 mm 50 ft 15 2 m 1 4 npsm f 214 703 3 8 9 5 mm 25 ft 7 6 m ...

Page 20: ... and Graco shall not be liable for any malfunction damage or wear caused by faulty installation misapplication abrasion corrosion inadequate or improper maintenance negligence accident tampering or substitution of non Graco component parts Nor shall Graco be liable for malfunction damage or wear caused by the incompatibility with Graco equipment of structures accessories equip ment or materials no...

Reviews: