Operation
332078C
43
Bleed Valves
Perform the procedure mechanically and if the dispense
head is plugged or there is no air to actuate the dis-
pense head solenoid.
Refer to the SR657-1M-LR Meter-Mix Dispense Sys-
tems, Operation manual for additional component call-
outs.
1. Press the stop button on the front of the machine.
2. Place a waste container below each Bleed Ball
Valve.
3. Open both Material Ball Valves.
4. Open the “A” Bleed Ball Valve. Residual pressure
will be relieved in the fluid lines between the pump
and the check valve.
5. Verify the analog pressure gauge reads 0 psi.
6. Repeat for the “B” Pump Bleed Valve.
Operation
Normal operation of the machine will take place in “Auto
Mode.” The metering unit will wait for a “screw rotate
signal” from the press or factory automation to start dis-
pensing material.
In the following step, any pressure in the lines will be
instantly relieved if no obstructions are within the
lines. This may lead to material spraying out of the
valve and splashing in the bucket. Use appropriate
protective wear to prevent contact with materials.
“A” Material
Pressure Gauge
“B” Material
Pressure Gauge
Summary of Contents for Fluid Automation 633
Page 10: ...Screen Navigation 10 332078C Screen Navigation ...
Page 11: ...Screen Navigation 332078C 11 ...
Page 12: ...Screen Navigation 12 332078C Refer to Screen 1 page 25 for mor details ...
Page 13: ...Screen Navigation 332078C 13 Refer to Screen 2 page 26 for mor details ...
Page 14: ...Screen Navigation 14 332078C Refer to Screen 3 page 26 for mor details ...
Page 15: ...Screen Navigation 332078C 15 Refer to Screen 4 page 27 for mor details ...
Page 16: ...Screen Navigation 16 332078C ...
Page 17: ...Screen Navigation 332078C 17 ...