Operation / Data Log
44
332305B
Technical Summary
The Technical Summary contains two types of data.
•
The first report only provides data compiled since
the Pump Summary was reset to present day (see
A6 - Clearing the Functional and Technical User
Summary).
This is very similar to the resettable trip odometer in
your car.
•
The second is a report that covers the cumulative
life of the pump from the first day it was put into ser-
vice to present day.
This is very similar to an odometer in your car.
The log file is stored as:
GRACO/G3_{DMS_id}/{download date - YYYYm-
mDD}/TECHSUM.CSV
Example: GRACO/G3_00025/20100911/TECH-
SUM.CSV
Common Technical Summary Data entries are listed
below.
Sample Technical Summary
Average Input Board
Voltage (DC)
The average input voltage mea-
sured by the internal circuit board.
Peak Input Board Volt-
age (DC)
The peak input voltage measured
by the internal circuit board.
Average Motor Current
The average motor current mea-
sured by the unit.
Peak Motor Current
The peak motor current mea-
sured by the unit.
Average Internal Tem-
perature
The average internal tempera-
ture seen by the unit.
Peak Internal Tempera-
ture
The peak internal temperature
seen by the unit.
Low Internal Tempera-
ture
The lowest internal temperature
seen by the unit.
G3 Technical Summary
DMS ID Number: 00025 (see page 38)
Software Part Number:16F821
Software Version: 0205
12/27/2010
9:50:51
Latest Values
Temp
Voltage
31C
23.877
Type
Start Date Average
Board
Voltage
Peak
Board
Voltage
Average
Motor
Current
Peak
Motor
Current
Average
Internal
Temp
Peak
Internal
Temp
Low
Internal
Temp
User
12/21/2010
23.877
23.877
0.062
0.06230C
35C
28C
Factory
9/30/2010
22.804
23.877
1.091
0.36233C
42C
-10C