Technical Data
311052E
39
Technical Data
Triggering Speed
These values apply to a new gun with a 6 ft. (1.8 m), 1/4 in. (6.3 mm) OD cylinder air line and a 0.019 in. tip. These
values will vary slightly with use and with variations in equipment.
Sound Data (dBa)
† Sound pressure measured 3.28 feet (1 meter) from equipment.
‡ Sound power measured per ISO-9614-2.
Maximum Working Fluid Pressure . . . . . . . . . . . . . . . . . . 4000 psi (28 MPa, 280 bar)
Maximum Working Air Pressure . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7 bar)
Maximum Working Fluid Temperature . . . . . . . . . . . . . . . 120° F (49° C)
Minimum Air Cylinder Actuation Pressure . . . . . . . . . . . . 50 psi (0.34 MPa, 3.4 bar)
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 lbs (965 g)
Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Stainless Steel, Carbide, Ultra High Molecular Weight
Polyethylene, Chemically Resistant Fluoroelastomer,
Engineered Plastic, PTFE, Polyamide
Models (3/16 in. ball)
Cylinder Air Pressure
psi (MPa, bar)
Fluid Pressure
psi (MPa, bar)
msec to fully open
msec to fully close
50 (0.34, 3.4)
600 (4.2, 42)
60
60
50 (0.34, 3.4)
1800 (12.4, 124)
60
60
50 (0.34, 3.4)
4000 (28, 280)
60
60
Air Cap
Part No.
Operating
Conditions
Fluid Pressure
with 0.019 in. tip
psi (MPa, bar)
Fan Air Pressure
psi (MPa, bar)
Atomizing Air
Pressure
psi (MPa, bar)
Sound
Pressure
dB(A)†
Sound
Power
dB(A)‡
288194
Rated Pressures
4000 (28, 276)
0
100 (0.7, 7)
100 (0.7, 7)
100 (0.7, 7)
91.75
91.22
91.90
91.46
Normal Operating
Pressures
600 (4.2, 42)
0
30 (0.21, 2.1)
30 (0.21, 2.1)
30 (0.21, 2.1)
83.87
84.41
76.28
78.65
Summary of Contents for G40