Installation
333011D
13
Fiber Optic Cable Connection
(Operational on Smart models only)
NOTE:
Only use the supplied fiber optic cable.
The fiber optic cable allows the gun to communicate
with the Pro Xp Auto control module.
For a 1 Gun System
1. Connect Port 1 of the gun 1 manifold to Port 1 of the
Control Module.
2. Connect Port 2 of the gun 1 manifold to Port 2 of the
Control Module.
For a 2 Gun System
1. Connect Port 1 of the gun 2 manifold to Port 5 of the
Control Module.
2. Connect Port 2 of the gun 2 manifold to Port 6 of the
Control Module.
F
IG
. 6 . Making Fiber Optic Connections
F
IG
. 7 . Fiber Optic Schematic
Non-Hazardous Area
Hazardous Area
U
V
H*
P
Q
Port 6
Port 5
Port 2
Port 1
1
2
R
Key for F
IGURE
7
H
Pro Xp Auto AA Gun
P
24 Volt Power Supply Connection
Q
Remote I/O Connection
R
Pro Xp Auto Control Module
U
Bulkhead (optional)
V
Fiber Optic Cable
* Approved for hazardous locations.
Gun 1
Gun 2
H
V
H*