308553ZAE
19
Service
Reassembly
1.
If the detent collar (7) was removed, carefully install a
new collar in a new cover (2), using a rubber mallet.
See F
2.
Grease the spring (6) and place it in the collar (7).
Grease the ball (8) and set it on the spring.
3.
Grease the o-ring (20) and install it in the hole (H) in
the cover (2). See F
. 12. Slide the washer (18) onto
the blunt end of the reset shaft (21). Insert the shaft
through the cover (2) until it seats.
4.
Grease the spring (3). Place the link stop (4) inside
the spring.
F
IG
. 12
____________________
5.
Grease the detent link (22) and link spacer (17).
Assemble the detent link, link spacer, and actuator
link (16) as shown in F
. 13. The raised bumps on
the links (22 and 16) must face up.
6.
Squeeze the spring (3) and install it and the stop (4)
in the link assembly. The spring tension will hold all
these parts together. Grease the valve cup (5) and
install it in the link assembly as shown.
7.
Install the link assembly on the cover (2) so the
pointed end of the reset shaft (21) fits through the
holes in the links and the square part of the shaft
engages the square hole. Make certain the bumps on
the detent link (22) engage the ball (8).
F
IG
. 13
____________________
01437
18
2
6
8
7
21
20
1
1
1
1
2
H
Apply grease (26†).
Press fit with rubber
mallet.
1
2
17
3
16
2
4
8
5
22
2
3
1
1
1
2
7505A
1
1
1
Apply grease (26†).
Bumps face up.
Reset shaft square must engage
with square hole.
1
2
3
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910