34
308553ZAE
Technical Data
Pumps with TPE or Buna-N Diaphragms
Maximum fluid working pressure ......... 100 psi (0.7 MPa, 7 bar)
Air pressure operating range20 to 100 psi (0.14 to 0.7 MPa, 1.4
to 7 bar)
Maximum air consumption ...................... 5.5 SCFM (see chart)
Maximum free flow delivery ...........................7 gpm (26.5 l/min)
Maximum pump speed ................................................. 330 cpm
Maximum suction lift ............. 12 ft (3.7 m) dry; 21 ft (6.4 m) wet
Maximum size pumpable solids .......................1/16 in. (1.6 mm)
Sound power level,
at full flow: (100 psi [0.7 MPa, 7 bar) .................... 85 dBa
Sound power level,
at 70 psi (0.48 MPa, 4.8 bar) and 1 gpm (3.8 lpm) 78 dBa
Operating temperature range.................................. 40 to 150
F
(4.4 to 65.5
C)
Air inlet size ..................................................................1/4 npt(f)
Fluid inlet and outlet size. .............................................3/8 npt(f)
Wetted Parts ................... Vary by model. See pages 28 and 30.
Acetal models include acetal with conductive sst fibers.
Non-wetted external parts. acetal, polyester (labels), glass-filled
polypropylene with conductive SST fibers, 303, 304 and 316
stainless steel
WeightAcetal Pumps: 5.25 lb (2.4 kg)
Polypropylene Pumps: 4.75 lb (2.2 kg)
* Sound power level measured per ISO standard 9614-2.
Santoprene
®
is a registered trademark of the Monsanto
Company.
0
20
40
60
80
100
120
0
1
2
3
4
5
6
7
8
(7.6)
(15.2)
(22.7)
(30.3)
(2.8)
(1.4)
(4.2)
280
(85.3)
240
(73.2)
200
(61.0)
160
(48.8)
120
(36.6)
80
(24.4)
40
(12.2)
0
0
20
40
60
80
100
0
5
10
15
20
25
(1.52)
(3.05)
(4.57)
(6.1)
(7.62)
(5.6)
(7.0)
(8.4)
(3.8)
(11.4)
(19.0)
(26.5)
Example of Finding Pump Air Consumption and Air Pressure at a Specific Fluid
Delivery and Discharge Head: To supply 3 gpm (11.4 liters) fluid flow (horizontal scale
at 50 psi (3.5 bar) discharge head pressure (vertical scale) requires 3 scfm (.084 m
³
/min
air consumption at 70 psi (4.9 bar) inlet air pressure.
feet
(meters)
psi
(bar)
100 psi air
(7 bar)
70 psi air
(4.9 bar)
40 psi air
(2.8 bar)
20 psi air
(1.4 bar)
3 scfm (0.084
m³/min)
5 scfm (0.14
m³/min)
PUMP DISCH
ARGE HEAD
PERCENTAGE OF
FLOW DECREASE
FLUID FLOW GPM (lpm)
KEY
FLUID PRESSURE AND FLOW
SCFM AIR CONSUMPTION
TEST CONDITIONS
Pump tested in water with inlet submerged.
PUMPING RATE DECREASE AT DIFFERENT SUCTION LIFTS
EXAMPLE: At a suction lift of 10 ft (3.05 m), the pump flow rate will be decreased by 20 percent.
SUCTION LIFT IN FEET (METERS)
Tel: 866-777-6060
Fax: 866-777-6383
Springer Pumps, LLC
Website: www.springerpumps.com
Int'l: +001 267 404 2910