Installation
6
3A8812B
Isolation Cabinet Bulkhead Fittings
1. Install three bulkhead fittings on the right side of the
isolation cabinet as shown in F
- EEO bulkhead fitting (J)
- ERI bulkhead fitting (K)
- PTI bulkhead fitting (L)
2. Label the ports on the outside of the cabinets as
shown in F
. 6 with provided labels (16).
Connect Pneumatic
Components
Connect Pressure Switches
Make the following connections inside the electronics
control panel. Use 5/32 in. bulkhead tubing.
1. Connect the PTI pressure switch (D) to the PTI
bulkhead fitting (G).
2. Connect the ERI pressure switch (E) to the ERI
bulkhead fitting (H).
Connect Bulkhead Fittings
Connect the following bulkhead fittings inside the
isolation cabinet. Use 5/32 in. bulkhead tubing (10).
1. Connect PTI bulkhead fitting (G) on the electronics
control panel to the PTI bulkhead fitting (L) on the
side of the cabinet.
2. Connect the control panel ERI bulkhead fitting (H)
on the electronics control panel to the ERI bulkhead
fitting (K) on the side of the cabinet.
3. Connect the EEO solenoid air fitting (FF) to the EEO
bulkhead fitting (J). See F
. 5.
F
IG
. 4 Pressure switch connections
G
H
D
E
F
IG
. 5 Bulkhead locations
J
K
L
G
H