background image

 Electrical Schematic

8

3A8812B

Electrical Schematic

ES TRIGGER OUT SOLENOID 16P316

C

ABLE 19Y758

 AIR FL

OW SWIT

CH

119159

TO TERMINAL BL

OCK 120491

OPT

O 3 17G392

OPT

O 3 17G392

13

14

OPT

O 2 17G392

OPT

O 2 17G392

A1+

A2-

TERMINAL BL

OCKS

120491

TERMINAL BL

OCKS

120491

13   14

5k Ohm

RESIS

TOR

17N992

BLK OR BRN 

BL

U OR RED

BLK OR BRN 

BLK OR BRN

BLK OR BRN

BL

U OR RED

BL

U OR RED

BL

U OR RED

BR1

BR2

BR3

BR4

  PRESSURE SWIT

CH

17D919

4 1 2

NO COM NC

GFB INPUT (KIT)

ST

OP INPUT (KIT)

ES INPUT

ES OUTPUT

LOW P

AINT OUTPUT

UNUSED

ST

OP DIGIT

AL INPUT

ST

ATUS OUTPUT (KIT)

INLET AIR

ES INPUT

1   2   3   4  5  

C

AN 1

C

AN 2

1 2 3 4 5

1 2 3 4 5

1 2 3 4

1 2 3 4

1

2

3

4

1 2 3 4 5 6 7 8

5

6

7

GC

A

FCM3 289696

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

J8

J15

J14

J9

J16

J10

SHUTTLE UP SOLENOID 16P316

SHUTTLE DOWN SOLENOID 16P316

SHUTTLE EJEC

T SOLENOID 16P316

SHUTTLE FL

UID IN SOLENOID 16P316

PUMP FL

UID IN SOLENOID 16P316

PUMP PRESSURE SOLENOID 16P316

GROUND ROD UP SOLENOID 16P316

J7

J11

19Y588

19Y588

COL

OR

CHANGE 25D312

  PRESSURE SWIT

CH

17D919

 

FL

UID V2P 17G386

C

ABLE 121000

( 17D923 )

ADM

C

ABLE 19Y758

C

ABLE 19Y572

1   2   3   4  5  

( 17D923 )

LINEAR POS. SENSOR 287839

TOP HALL 24W120

BO

TT

OM

HALL 24W120

TO FL

UID V2P 19Y572

1 2 3 4 5 1 2 3 4 5

1

2

C

ABLE

19Y586

C

ABLE

19Y759

C

ABLE

17H111

1  BROWN 2  WHITE 3  BL

UE

4  BLA

CK

5  DRAIN

TERMINAL BL

OCKS

120491

TERMINAL BL

OCKS

120491

1   2

3   4

P2

P3

P4

KV  BO

ARD

26C727

1 2 3 4 5

1 2 3

TO C

ABLE 19Y586

6 J2

4 1 2

P1

P2

J1

P2

OPT

O 1 17G392

OPT

O 1 17G392

TERM BLK 120491

TERM BLK 120491

13

14

7

8

BR1

BR2

BRN OR RED

BRN OR RED

BL

U OR BLK

BL

U OR BLK

NO COM NC

BR1

BR2

BR3

BR4

BLK OR BRN 

BL

U OR RED

BLK OR BRN 

BLK OR BRN

BLK OR BRN

BL

U OR RED

BL

U OR RED

BL

U OR RED

TO EAR

TH

GROUND

BLEED RESIS

TOR

TO CHARGED

PA

R

TS

25R034

11   12

  AIR V2P 17G386

C

ABLE 19Y572

1   2   3   4  5  

TO C

ABLE 19Y586

6 J1

P1

P2

J1

TO AIR V2P 19Y572

P2

5   6

PAINT TRIGGER

  PRESSURE SWIT

CH

17D919

4 1 2

NO COM NC

Summary of Contents for HydroShield 26D030

Page 1: ...ility to a manual HydroShield system For professional use only Model 26D030 100 psi 0 7 MPa 7 0 bar Maximum Air Working Pressure Important Safety Instructions Read all warnings and instructions in this manual and in the related manuals before using the equipment Save all instructions ...

Page 2: ...glish Description Air Assisted Spray Included with air assisted manual isolation systems Use before conversion and during air assisted manual spraying 3A7370 HydroShield Air Assisted Spray Batch Waterborne Isolation Systems Air Spray Included with air spray manual isolation systems Use before conversion and during manual air spraying 3A7312 HydroShield Air Spray Batch Waterborne Isolation Systems ...

Page 3: ...tput will be active This will signal the spray gun to turn on electrostatics This signal connects the isolation cabinet and the device that will enable electrostatics Low Paint Output LPO The Low Paint Digital output provides a means to signal when the system is low on paint and when the system has refilled It is based on the user adjustable green on and red on light tower settings The output is a...

Page 4: ...four hex screws on the electronics control panel and pull off the cover Upper DIN Rail Components Install the following components from right to left on the upper DIN rail See FIG 1 1 Install the ERI optocoupler A next to the existing optocoupler and match the orientation 2 Install the LPO optocoupler B in the opposite orientation 3 Install terminal blocks C11 C14 Label the blocks11 14 with the pr...

Page 5: ...oid F and the EEO solenoid air fitting FF in the lower most location of the manifold See FIG 2 Install Bulkhead Fittings Remove hole plugs as needed and install bulkhead fittings inside the isolation cabinet Electronics Control Panel Bulkhead Fittings 1 Install two bulkhead fittings to the bottom of the electronics control panel in the following order see FIG 4 PTI bulkhead fitting G ERI bulkhead ...

Page 6: ...e PTI pressure switch D to the PTI bulkhead fitting G 2 Connect the ERI pressure switch E to the ERI bulkhead fitting H Connect Bulkhead Fittings Connect the following bulkhead fittings inside the isolation cabinet Use 5 32 in bulkhead tubing 10 1 Connect PTI bulkhead fitting G on the electronics control panel to the PTI bulkhead fitting L on the side of the cabinet 2 Connect the control panel ERI...

Page 7: ...ponents 3 Install the resistor 14 between terminal block 11 C11 and terminal block 12 C12 NOTE Install the resistor on the bottom side of the terminal blocks 4 Connect the ERI optocoupler A and ERI pressure switch E with jumper wires 8 and white ferrules 9 5 Connect the PTI pressure switch D to terminal blocks C5 and C6 with jumper wires 8 with the white ferrules 9 6 Wire the EEO solenoid F to loc...

Page 8: ...16P316 SHUTTLE FLUID IN SOLENOID 16P316 PUMP FLUID IN SOLENOID 16P316 PUMP PRESSURE SOLENOID 16P316 GROUND ROD UP SOLENOID 16P316 J7 J11 19Y588 19Y588 COLOR CHANGE 25D312 PRESSURE SWITCH 17D919 FLUID V2P 17G386 CABLE 121000 17D923 ADM CABLE 19Y758 CABLE 19Y572 1 2 3 4 5 17D923 LINEAR POS SENSOR 287839 TOP HALL 24W120 BOTTOM HALL 24W120 TO FLUID V2P 19Y572 1 2 3 4 5 1 2 3 4 5 1 2 CABLE 19Y586 CABLE...

Page 9: ...ic communication for electrostatic operation signals ERI and EEO Pneumatic ERI and EEO Option 1 Connect a 5 32 in air line from the EEO bulkhead fitting J to the input of the device that activates electrostatics 2 Connect a 5 32 in air line to the ERI bulkhead fitting K Supply air pressure above 70 psi 0 5 MPa 5 0 bar to activate the input Electric ERI Option 1 Run a 24 VDC signal wire and a groun...

Page 10: ...is active there is 24V present 5 Connect terminal block 12 C12 to the ground wire NOTE Terminal block 11 C11 signal voltage is optically isolated at Graco electrostatic controllers If using any other controller be sure to use an optocoupler at the input to the device Wire LPO Optocoupler 1 LPO optocoupler B ports A1 and A2 are wired to the control module 2 Wire LPO optocoupler B ports 13 and 14 to...

Page 11: ...te automatic system manual to properly configure the system on the setup screen See Included Manuals page 2 Convert Back to a Manual System NOTE The converted system can be used in either manual or automatic mode 1 Disable the paint trigger and electrostatic inputs going to the system NOTE These input signals will cause alarms if they re active while converting back to a manual system 2 Disable Au...

Page 12: ...Parts 12 3A8812B Parts Model 26D030 17 2 5 7 11 4 6 10 1 12 14 9 15 16 13 8 3 ...

Page 13: ...itch includes D and E 2 7 121818 bulkhead fitting fits 5 32 in tube includes L K J G and H 5 8 copper electrical wire 3 feet 1 9 112513 ferrule wire white 8 10 598095 nylon tube 5 32 od 10 feet 1 11 120491 terminal block includes C11 C12 C13 and C14 4 12 120490 end cover 2 13 terminal block labels 11 20 2 14 resistor 5k ohms 5 1 2 watt 1 15 control box labels 1 16 cabinet labels 1 17 rail mount 39...

Page 14: ...n material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warr...

Reviews: