System errors alert the operator of a problem in the
system. When any error occurs:
• Error buzzer sounds (unless operating in silent
mode).
• An error popup screen displays the active error
code.
• The Status bar displays the active error code.
The error is saved in the error or event log.
There are four types of error: Alarm, Deviation,
Advisory, and Record.
If an Alarm
Alarm
Alarm occurs, operation stops and an error is
recorded in the system.
A Deviation
Deviation
Deviation records an error in the system but does
not shut down the equipment. The deviation must be
acknowledged by the user.
An Advisory
Advisory
Advisory records an event in the system and
clears itself after 60 seconds.
A Record
Record
Record saves relevant system events in the
background. This information can be reviewed on
the Error Log Screen.
To
To
To Clear
Clear
Clear Error
Error
Error and
and
and Restart
Restart
Restart
When a deviation or alarm occurs, be sure to
determine the error code before resetting it. Go to
the Events Screen to view the last 200 errors, with
date and time stamps. See
.
If an alarm has occurred, correct the cause before
resuming operation.
To acknowledge a deviation or clear an alarm, press
.
Table
Table
Table 6
6
6 System
System
System Logic
Logic
Logic Controller
Controller
Controller Errors
Errors
Errors
Code
Code
Code
Type
Type
Type
Name
Name
Name
Description
Description
Description
Solution
Solution
Solution
EVUX
Advisory
USB Disabled
User installed a USB
device in the system
logic controller USB
port when USB
downloads were
disabled.
Go to Screen X and enable USB.
WSUX
Advisory
USB Configuration
Error
USB configuration
file does not match
expected; checked on
startup.
Reinstall software.
WXUU
USB Upload Error
WXUD
Advisory
USB Download Error
User installed an
incompatible USB
device in the System
Logic Controller USB
port.
Repeat process with compatible USB
device.
WX00
Alarm
Software Error
An unexpected
software error has
occurred.
Call Graco technical support.