Table
Table
Table 7
7
7 Communications
Communications
Communications Errors
Errors
Errors
Code
Code
Code
Type
Type
Type
Name
Name
Name
Description
Description
Description
Solution
Solution
Solution
CAD1
Alarm
Communication Error
Fluid Panel
The control
interface has lost
communication with
the fluid panel or FCM
cube.
• Verify CAN connection on system.
• Verify CAN connection on the FCM
cube.
• Check status LEDs on FCM cube.
• Cycle power.
CAC1
Alarm
Communication Error
Solenoid Controller
The control
interface has lost
communication
with the solenoid
controller.
• Verify CAN connection on system.
• Verify CAN connection on solenoid
controller board.
• Check status LEDs on solenoid
controller board.
• Cycle power.
CDD0
Alarm
Duplicate Fluid Panel
The system detects
multiple fluid panels
set to the same
identifier.
• The fluid panel FCM has the same
CAN ID as another module.
• Adjust the selector switch on the
control module. See Adjusting
Selector Switch in manual 3A3954.
CDC0
Alarm
Duplicate Solenoid
Controller
The system detects
multiple solenoid
controllers set to the
same identifier.
• The solenoid controller has the
same CAN ID as another module.
• Adjust the selector switches on
solenoid controller board.
CAO1
Alarm
Communication Error
Logic Controller
The system has lost
communication with
the logic controller.
• Verify CAN connection on the
bottom of the System Logic
Controller.
• Check the status LEDs on the
System Logic Controller. See
Diagnostic Information, page 53
3A7370B