System
System
System
Pump
Pump
Pump Ratio:
Ratio:
Ratio: The ratio of the Merkur pump for the
high pressure supply in air-assisted systems. The
ratio is set in the factory according to the system
model. For ratio information, see
Gun
Gun
Gun Flush
Flush
Flush Box:
Box:
Box: Enable if using a gun flush box.
Fill
Fill
Fill Start
Start
Start Delay:
Delay:
Delay: the number of seconds that the
system waits after the gun trigger is released before
it lowers the isolation valve (G) and the system
discharges.
During the course of a spraying operation, the
operator may need to briefly release the gun trigger
before painting another part. Increase the time if you
want the charge to last longer after the gun trigger is
released. (Default: 2 seconds.)
The length of time between when the gun trigger is
released and system discharge is a combination of
two settings: the Ground Rod Delay time and the Fill
Start Delay time.
For example, if the Fill Start Delay is set to 7 and the
Ground Rod Delay is set to 5:
1.
The gun trigger is released.
2.
After 5 seconds the ground rod lowers.
3.
In 2 more seconds the isolation valve lowers.
The actual time that the system takes to discharge
depends on these settings, the gun type, and the
hose length.
Ground
Ground
Ground Rod
Rod
Rod Delay:
Delay:
Delay: The number of seconds that the
system waits after the gun trigger is released before
it lowers the ground rod (N), instantly dissipating the
charge.
Restart
Restart
Restart System:
System:
System: Select this box to restart the entire
system. This is primarily used for initiating a token
software update without manually cycling the power.
50
3A7370B