Blink
Blink
Blink Code
Code
Code
Error
Error
Error Type
Type
Type
Troubleshooting
Troubleshooting
Troubleshooting Steps
Steps
Steps
5
Deviation
Low
Low
Low Temperature
Temperature
Temperature
• Warm equipment.
• Circuit board cannot read the temperature sensor. Check if the sensor is plugged
into the correct connector. See the Driver manual,
6
Alarm
Motor
Motor
Motor Temperature
Temperature
Temperature Fault
Fault
Fault
Motor is running too hot. Allow unit to cool.
• Reduce pressure.
• Move the unit to a cooler location.
7
Alarm
Board
Board
Board Temperature
Temperature
Temperature Fault
Fault
Fault
The control board is running too hot. Allow the unit to cool.
• Reduce pressure.
• Move the unit to a cooler location.
8
Alarm
Encoder
Encoder
Encoder Calibration
Calibration
Calibration Error
Error
Error
• Cycle power and check status indicator (L) to see if the error is still active.
• Follow the calibration procedure listed in the King Driver Operation/Repair
manual to calibrate the encoder (this code will blink if calibration is in progress).
• Contact your Graco distributor or Tech Service for more information.
9
Alarm
Encoder
Encoder
Encoder Error
Error
Error
• Cycle power and check the status indicator (L) to see if the error is still active.
• Verify that the internal connections are intact.
• Contact your Graco distributor or Tech Service for more information.
10
Alarm
Software
Software
Software Versions
Versions
Versions Do
Do
Do Not
Not
Not Match
Match
Match
• Obtain software update token. See Accessories
Accessories
Accessories section for token part number.
See the Driver Operation/Repair manual for token installation information.
11
Alarm
Circuit
Circuit
Circuit Board
Board
Board Communication
Communication
Communication Failure
Failure
Failure
• Cycle power and check status indicator (L) to see if the error is still active.
• Contact your Graco distributor or Tech Service for more information.
12
Alarm
Internal
Internal
Internal Circuit
Circuit
Circuit Board
Board
Board Hardware
Hardware
Hardware Failure
Failure
Failure
• Cycle power and check status indicator (L) to see if the error is still active.
• Contact your Graco distributor or Tech Service for more information.
13, 14
Alarm
Internal
Internal
Internal Software
Software
Software Error
Error
Error
• Cycle power and check status indicator (L) to see if the error is still active.
• Contact your Graco distributor or Tech Service for more information.
Slow Blink
Deviation
See
.
24