Troubleshooting
3A2333B
17
Sprayer Will Not Run
(See following page for steps)
Remove control box cover. Turn
sprayer ON. Observe control
board status light on control board
(see page 12).
No light
Once
Normal operation
Light on
Continuously
Control board
commanding
motor to run
Flashing
See Error Code
section for further
troubleshooting
Connect a test
transducer to the
board. Does the
motor run?
Replace
potentiometer.
See Step 3. Is the
proper reading
present through the
thermal switch
wires?
Replace the
ON/OFF switch.
See step 4. Does
the motor run?
See Step 1. Do
you have over 100
AC volts (220 for
230V units)?
See Step 2. Do
you have over
100 AC
(220 for
230 VAC units)?
Repair or
replace
power cord.
If motor is hot, let cool and
retest. If Step 3 still shows
incorrect resistance, replace
motor. The motor has
a defective thermal device.
Replace the
transducer
Replace the
control board.
YES
YES
YES
NO
NO
NO
NO
YES
YES
NO