Setup
4
Setup
Location
•
The system should always be used on a level
surface.
•
Do not expose the system to rain.
Electrical Requirements
•
Required power source: single dedicated circuit that
is rated at a minimum of 15A.
NOTE:
Cords must be 3-conductor grounded, rated for
your environment.
•
Power cord connector (120V):
One NEMA 5-15T
•
Extension cord requirements:
Grounding
System:
grounded through power cord.
Generator (if used):
follow your local code and
manufacturer
’
s recommendations. Start and stop the
generator with power cord(s) disconnected.
Spray gun:
ground through connection to a properly
grounded fluid hose and system.
Fluid supply container:
follow local code.
Object being sprayed:
follow local code.
Solvent pails used when flushing:
follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a nonconductive
surface, such as paper or cardboard, which interrupts
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure:
hold metal part of the spray gun
firmly to the side of a grounded metal pail, then trigger
the gun.
Required Wire Size
Up to 50 ft (15 m)
Up to 100 ft (30 m)
AWG 14
AWG 12
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.