Fig 13
KEY
A
Megohmmeter
17 Air Fitting
20 Electrode
17
A
20
2
Refer to this drawing in place of the typical installation drawing on page 4:
WARNING
F*
P*
Q*
C*
A*
L*
K*
M
B
H*
E
N*
R
T
U*
*Equipment that must be installed for safe operation of a water-base system
G
X*
W*
Y*
03585
To Gun
To Gun
J*
S*
V*
On page 22:
Test Gun Resistance
Change the procedure to the following:
Measure the resistance between the electrode (20) and
the gun air fitting (17). See Fig. 13. The resistance should
be between 180 to 220 megohms. If the resistance is
outside the specified range, go to the next test. If the
resistance is correct, test the resistor stud resistance as
shown on page 23.
On page 23:
Test Resistor Stud Resistance
The resistance should be 21 to 29 megohms instead of
22.5 to 27.5 megohms.
Summary of Contents for PRO 3500WB
Page 11: ... NOTES ...
Page 35: ... NOTES ...