Operation
309297K
19
Adjust the Spray Pattern
Follow the steps below to establish the correct fluid flow
and air flow. Do not turn on the turbine air (TA) yet.
1.
Relieve the pressure.
2.
Loosen the air cap retaining ring, and rotate the air
cap for a vertical or horizontal spray pattern. See
F
11. Tighten the retaining ring until the air
cap is held firmly in place; you should not be able to
rotate the air cap horns by hand.
Fig. 11. Air Cap Positions
3.
Adjust the fluid flow with the fluid pressure regulator.
Refer to instruction manual 309419 to set the fluid
pressure for various fluid flows, according to the size
of the fluid nozzle being used.
4.
Use the air pressure regulator on the atomization air
supply line (A1) to adjust the degree of atomization.
See F
12. For example, for a fluid flow rate of
10 ounces per minute (0.3 liters per minute), a typi-
cal atomization pressure would be 20-30 psi
(1.4-2.1 bar, 0.14-0.21 MPa) at the gun manifold.
5.
Use the air pressure regulator on the fan air supply
line (A2) to adjust the pattern size.
•
For the most efficiency, always use the lowest air
pressure possible.
•
When increasing to a wide, flat pattern, it may be
necessary to increase the supply of fluid to the gun
to maintain the same amount of coverage over a
large area.
•
See Spray Pattern Troubleshooting on page 29 to
correct spray pattern problems.
Fig. 12. Manifold Air Connections
WARNING
Pressurized Equipment Hazard
To reduce the risk of an injury, follow the
Pressure Relief Procedure on page 17
whenever you are instructed to relieve the
pressure.
Vertical Pattern
Horizontal Pattern
TI1577A