Maintenance
309297K
25
Check for Fluid Leakage
During operation, periodically check the manifold
exhaust tube (YY) and both ends of the gun shroud (ZZ)
for the presence of fluid. See F
14. Fluid in these
areas indicates leakage into the shroud, which could be
caused by leaks at the fluid tube connections or fluid
packing leakage.
If fluid is seen in these areas, stop spraying immedi-
ately. Relieve the pressure, then remove the gun for
repair.
Fig. 14. Check for Fluid Leakage
WARNING
Fire and Explosion Hazard
If any fluid leakage from the gun is
detected, stop spraying immediately. Fluid
leakage into the gun shroud could cause
fire or explosion and result in serious injury
and property damage.
WARNING
Pressurized Equipment Hazard
To reduce the risk of an injury, follow the
Pressure Relief Procedure on page 17
when you stop spraying and whenever you
are instructed to relieve the pressure.
ti1571a
TI1579A
YY
YY
ZZ
ZZ