Warning
4
309297K
WARNING
Fire, Explosion, and Electric Shock Hazard
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help
prevent fire and explosion:
•
Electrostatic equipment must be used only by trained, qualified personnel who understand the
requirements of this manual.
•
Ground equipment, personnel, object being sprayed, and conductive objects in work area. See
Grounding instructions.
•
Only use grounded Graco conductive air supply hoses.
•
Check gun and hose resistance and electrical grounding daily.
•
Use and clean equipment only in well ventilated area.
•
Interlock the gun air supply to prevent operation unless ventilating fans are on.
•
Use cleaning solvents with highest possible flash point when flushing or cleaning equipment.
To comply with EN50050 requirements, cleaning solvents must have a flash point at least 5°C
above ambient temperature.
•
Always turn the electrostatics off when flushing, cleaning or servicing equipment.
•
If there is static sparking or you feel a shock, stop operation immediately. Do not use equip-
ment until you identify and correct the problem.
•
Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plas-
tic drop cloths (potential static arc).
•
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
•
Keep work area free of debris, including solvent, rags and gasoline.
•
Keep a working fire extinguisher in the work area.
Toxic Fluid Hazard
Hazardous fluids or toxic fumes can cause a serious injury or death if splashed in the eyes or on
the skin, swallowed, or inhaled.
•
Know the specific hazards of the fluid you are using. Read the fluid manufacturer’s warnings.
•
Store hazardous fluid in an approved container. Dispose of the hazardous fluid according to all
local, state, and national guidelines.
•
Wear appropriate protective clothing, gloves, eyewear, and respirator.
Summary of Contents for PRO Auto Xs Series
Page 44: ...Repair 44 309297K Notes ...