Repair
46
309457G
Adjust the Actuator Arm
NOTE: The fluid nozzle (4) must be in place when
removing or installing the jam nut and actuator arm.
1.
Install the adjustment nut (30), actuator arm (29),
and jam nut (28) onto the piston rod (34b). Note that
the jam nut (28) has a slightly larger hex and a thin-
ner profile than the adjustment nut (30). See F
2.
Position the parts so there is a 0.125 in. (3 mm) gap
between the actuator arm (29) and the fluid packing
rod nut (E), which allows the atomizing air to actuate
before the fluid. See F
3.
Tighten the adjustment nut (30) against the actuator
arm (29). Check that the 0.125 in. (3 mm) gap has
been maintained. In addition, there should be 3-4
mm of electrode needle travel when the gun is trig-
gered. Adjust the jam nut position to obtain these
dimensions.
4.
Test gun resistance, page 30.
5.
Install the gun shroud (2) and air cap (3), page 41.
6.
Install the gun onto the manifold and bracket. See
page 40.
Fig. 29. Actuator Arm Adjustment
TI1567A
28
29
30
34b
E
0.125 in. (3 mm) gap
Summary of Contents for PRO Auto Xs
Page 51: ...Repair 309457G 51 ...