Introduction
309457G
7
•
The optional fiber optic readout system can be
installed to monitor the gun’s spraying voltage. A
fiber optic cable connected to the gun manifold car-
ries the signal from the gun to a remote display
module. Part No. 224117 Display Module displays
the gun’s spraying voltage and current. Bat-
tery-operated Display Module 189762 displays the
gun’s spraying voltage only.
Operating the Spray Function
Applying a minimum of 50 psi (0.35 MPa, 3.5 bar) air
pressure to the gun manifold’s cylinder air fitting (CYL)
will retract the gun piston, which opens the air valves
and a short time later opens the fluid needle. This pro-
vides the proper air lead and lag when triggering the
gun. A spring returns the piston when the cylinder air is
shut off.
Operating the Electrostatics
To operate the electrostatics, apply air pressure to the
gun manifold’s turbine air fitting (TA) through a Graco
grounded air hose. The air enters the manifold and is
directed to the inlet of the power supply turbine. The air
spins the turbine, which then provides electrical power
to the internal high voltage power supply. The fluid is
charged by the spray gun electrode. The charged fluid is
attracted to the nearest grounded object, wrapping
around and evenly coating all surfaces.
The turbine air is exhausted into the shroud and out the
back of the manifold through the exhaust fitting (EXH).
The exhaust air helps keep contaminants out and helps
keep the gun clean.
Changing the kV Setting
The gun’s full voltage setting is 60 kV. Three lower volt-
age settings are possible by actuating the KV1 and KV2
switches. Supply 50 psi (0.35 MPa, 3.5 bar) air pressure
to the KV1 and KV2 ports. Turn the air on or off as
shown in Table 1 to set the desired voltage.
NOTE: The solenoid valves used to activate the KV1
and KV2 switches must bleed the air out of the lines for
the switches to draw back to the higher voltage setting.
WARNING
Electric Shock Hazard
To reduce the risk of electric shock, do not
use the Graco ES Display Module readings
to determine if your system is discharged.
The display modules will only display the system volt-
age while the gun’s power supply is operating. Follow
the Fluid Voltage Discharge and Grounding Pro-
cedure on page 21 to ensure the system is dis-
charged.
Table 1: Low Voltage Adjustment
1
2
kV
ON
ON
35
ON
OFF
40
OFF
ON
50
OFF
OFF
60